eaton
TO-1-102/1/SVB
Category Parameter Specification Application Protected Circuit Analog signals (e.g., 4-20 mA) Connection In-series with the signal line Electrical Characteristics Nominal Voltage 8 V DC Max. Operating Voltage 12 V DC Nominal Current ≤ 250 mA Voltage Drop Typically < 1 V Surge Protection Performance Test Waveform (IEC 61643-21) 1.2/50 μs (Voltage) - 8/20 μs (Current) Nominal Discharge Current (In) 5 kA (8/20 μs) Max. Discharge Current (Imax) 10 kA (8/20 μs) Protection Level (Up) < 25 V (at In = 5 kA, 8/20 μs) General Data Number of Channels 1 Connection Type Screw terminals Mounting 35 mm DIN Rail Housing Material Plastic (PA 6.6) Operating Temperature -40 °C to +80 °C Standards / Approvals IEC 61643-21, CE

More details >> Request a Quote >>
eaton
T0-2-15679/11/SVB
Category Parameter Specification Application Protected Circuit 2-wire Analog signals (e.g., 4-20 mA loops) Connection In-series with the signal line Electrical Characteristics Nominal Voltage 8 V DC Max. Continuous Operating Voltage Uc 12 V DC Nominal Current ≤ 250 mA Voltage Drop Typically < 1 V Insertion Loss Typically negligible Surge Protection Performance Test Waveform (IEC 61643-21) 1.2/50 μs (Voltage) - 8/20 μs (Current) Nominal Discharge Current (In) 5 kA (8/20 μs) Max. Discharge Current (Imax) 10 kA (8/20 μs) Protection Level (Up) < 25 V (at In = 5 kA, 8/20 μs) General Data Number of Poles / Channels 2 (for series connection in one signal loop) Connection Type Screw terminals Mounting 35 mm DIN Rail Housing Material Plastic Operating Temperature -40 °C to +80 °C Standards / Approvals IEC 61643-21, CE

More details >> Request a Quote >>
eaton
T0-2-1/E
Category Parameter Specification / Typical Value Application & Configuration Protected Circuit Signal circuits (e.g., 4-20 mA, digital I/O) Circuit Configuration 2-pole (Line-to-Line and Line-to-Ground protection) Connection In-series with the signal line Electrical Characteristics Nominal Voltage 8 - 24 V DC (Typical for signal applications) Max. Continuous Operating Voltage (Uc) ~30 V DC (Please verify in datasheet) Nominal Current (In) Up to 250 mA (Suitable for most signal loops) Voltage Drop < 1.5 V (Low, to minimize impact on the signal) Surge Protection Performance Standards Complies with IEC 61643-21 Nominal Discharge Current (In) 5 kA (8/20 μs waveform) Max. Discharge Current (Imax) 10 kA (8/20 μs waveform) Protection Level (Up) < 40 V (at In, typical for this class) General Data Mounting 35 mm DIN Rail Connection Type Screw terminals Housing Material Plastic (PA 6.6) Operating Temperature -40 °C to +80 °C Status Indication None (This is a basic model without visual fault indicator)

More details >> Request a Quote >>
eaton
P3-63/14/SVB/H11
Category Parameter Specification / Typical Value Input Characteristics Input Voltage 100 - 240 VAC (Wide Range, Auto-Sensing) Input Frequency 50 / 60 Hz Input Current Max. ~1.5 A @ 100 VAC Inrush Current Limiting Yes Output Characteristics Output Voltage Approx. 14 V DC (Critical: Must verify with datasheet) Rated Output Current ~4.5 A (Calculated from 63W / 14V) Rated Output Power 63 W Efficiency Typically > 89% (High efficiency characteristic of P3 series) Ripple and Noise Typically < 100 mVpp Line Regulation < 0.5% Load Regulation < 0.5% Monitoring & Signaling Signal Contact (H11) DC-OK Relay (Floating changeover contact) Contact Rating Typically 24V DC / 2A (or 230V AC / 2A) Function Closes when output voltage is normal; opens on failure. Protection & Safety Overload Protection Electronic, auto-recovery Overvoltage Protection Electronic, auto-recovery Short-Circuit Protection Yes, electronic with auto-recovery Standards CE, cULus Listed, GL (Marine) Environmental & Mechanical Operating Temperature -25 °C to +70 °C (with derating above 60°C) Cooling Method Fanless (Convection) Mounting Standard 35 mm DIN Rail Protection Rating IP20 Connections Screw Terminals

More details >> Request a Quote >>
eaton
TO-2-1/1/SVB
Category Parameter Specification Application Protected Circuit 2-wire Analog signals (e.g., 4-20 mA loops) Connection In-series with the signal line Electrical Characteristics Nominal Voltage 8 V DC Max. Continuous Operating Voltage Uc 12 V DC Nominal Current ≤ 250 mA Voltage Drop Typically < 1 V Insertion Loss Typically negligible Surge Protection Performance Test Waveform (IEC 61643-21) 1.2/50 μs (Voltage) - 8/20 μs (Current) Nominal Discharge Current (In) 5 kA (8/20 μs) Max. Discharge Current (Imax) 10 kA (8/20 μs) Protection Level (Up) < 25 V (at In = 5 kA, 8/20 μs) General Data Number of Poles / Channels 2 (for series connection in one signal loop) Connection Type Screw terminals Mounting 35 mm DIN Rail Housing Material Plastic Operating Temperature -40 °C to +80 °C Standards / Approvals IEC 61643-21, CE

More details >> Request a Quote >>
eaton
P3-63/14/SVB/HI11
Category Parameter Specification / Typical Value Input Characteristics Input Voltage 100 - 240 VAC (Wide Range, Auto-Sensing) Input Frequency 50 / 60 Hz Input Current Max. ~1.5 A @ 100 VAC Inrush Current Limiting Yes, NTC thermistor Output Characteristics Output Voltage Approx. 14 V DC (Critical: Must verify actual value with datasheet) Rated Output Current ~4.5 A (Calculated from 63W / 14V) Rated Output Power 63 W Efficiency Typically > 89% (Characteristic of high-end P3 series) Ripple and Noise Typically < 100 mVpp Line Regulation < 0.5% Load Regulation < 0.5% Monitoring & Signaling (HI11 Option) Signal Contact DC-OK Relay (Floating changeover contact) Contact Rating Typically 24V DC / 2A (or 230V AC / 2A) Function Changes state when output voltage is within normal range; indicates power failure. Protection & Safety Overload Protection Electronic, auto-recovery Overvoltage Protection Electronic, auto-recovery Short-Circuit Protection Yes, electronic with auto-recovery Standards CE, cULus Listed, GL (Marine) Environmental & Mechanical Operating Temperature -25 °C to +70 °C (with derating above 60°C) Cooling Method Fanless (Convection) Mounting Standard 35 mm DIN Rail Protection Rating IP20 Connections Screw Terminals

More details >> Request a Quote >>
eaton
P3-63/EA - 63W
Category Parameter Specification / Typical Value Input Characteristics Input Voltage 100 - 240 VAC (Wide Range, Auto-Sensing) Input Frequency 50 / 60 Hz Inrush Current Limiting Yes Output Characteristics Output Voltage Likely 24 V DC (Must be verified with datasheet - other voltages like 12V or 48V are possible) Rated Output Current ~2.6 A (if output is 24V) Rated Output Power 63 W Efficiency Typically > 89% Ripple and Noise < 100 mVpp Redundancy Function Redundancy Capability Yes, designed for parallel operation Key Component Integrated OR-ing diode to prevent reverse current Load Sharing Typically not active current sharing; relies on diode decoupling Protection & Safety Overload Protection Electronic, auto-recovery Overvoltage Protection Electronic, auto-recovery Short-Circuit Protection Yes Standards CE, cULus Listed Environmental & Mechanical Operating Temperature -25 °C to +70 °C (with derating above 60°C) Cooling Method Fanless (Convection) Mounting Standard 35 mm DIN Rail Connections Screw Terminals

More details >> Request a Quote >>
eaton
EPF31P-M304V1O2PS
Category Parameter Specification / Typical Value Electrical Ratings Rated Voltage 300 VAC (3~ + PE) Rated Current ~16 A (Critical: Must verify exact value with datasheet - common values are 16A, 20A, 30A for this form factor) Frequency 50/60 Hz Test Standards Safety Standards UL 60939, IEC 60939, EN 60939 EMC Standards Designed to meet CISPR 11/32, EN 55011/55032 Filter Performance Insertion Loss > 60 dB (Typical at 1 MHz) > 40 dB (Typical at 100 kHz) Leakage Current Line to Ground Typically < 5 mA (at 250VAC, 50Hz) General Data Number of Phases 3-Phase + Protective Earth (PE) Connection Type Screw Terminals (for both line and load sides) Mounting Through-hole or bracket mounting (panel mount) Operating Temperature -25 °C to +100 °C Housing Material Metal case (typically aluminum) for shielding

More details >> Request a Quote >>
eaton
EF2TO006S6
Category Parameter Specification / Typical Value Motor Protection Setting Current Range (Iᵣ) 0.06 - 0.6 A (This is the core protective range) Tripping Class 10 (Standard) / 20 (e.g., for high-inertia loads) - Selectable Protection Functions • Overload • Phase Loss / Unbalance • Jam Protection (with adjustable trip time) • Earth Fault Protection (optional, depends on version) Electrical Characteristics Rated Operational Voltage (Uᵢ) Up to 690 V AC Supply Voltage (for electronics) Typically 24-240 V AC/DC (Auxiliary voltage for the relay's own circuitry) Contacts Output Auxiliary Contacts • 1 NO (95-96) - Fault Signal • 1 NC (97-98) - Fault Signal Rated Current of Aux. Contacts Typically 6 A General Data Mounting Snap-on to compatible Eaton contactors (e.g., DILM series) Standards IEC/EN 60947-4-1, UL 508 Status Indication LED indicators for "Ready", "Alarm/Trip" Ambient Temperature -20 °C to +60 °C

More details >> Request a Quote >>
eaton
TO-2-1/E
Category Parameter Specification / Typical Value Application & Configuration Protected Circuit Signal circuits (e.g., 4-20 mA, digital I/O) Circuit Configuration 2-pole (Line-to-Line and Line-to-Ground protection) Connection In-series with the signal line Electrical Characteristics Nominal Voltage 8 - 24 V DC (Typical for signal applications) Max. Continuous Operating Voltage (Uc) ~30 V DC (Please verify in datasheet) Nominal Current (In) Up to 250 mA (Suitable for most signal loops) Voltage Drop < 1.5 V (Low, to minimize impact on the signal) Surge Protection Performance Standards Complies with IEC 61643-21 Nominal Discharge Current (In) 5 kA (8/20 μs waveform) Max. Discharge Current (Imax) 10 kA (8/20 μs waveform) Protection Level (Up) < 40 V (at In, typical for this class) General Data Mounting 35 mm DIN Rail Connection Type Screw terminals Housing Material Plastic (PA 6.6) Operating Temperature -40 °C to +80 °C Status Indication None (This is a basic model without visual fault indicator)