Products
Products
home
eaton
DS7-342SX055N0-N
Category Parameter Specification / Typical Value Electrical Ratings Rated Voltage 342 VAC (3~ + PE) Rated Current 55 A Frequency 50/60 Hz Test Standards Safety Standards UL 60939, IEC 60939, EN 60939 EMC Standards Designed to meet CISPR 11/32, EN 55011/55032 Filter Performance Insertion Loss > 60 dB (Typical at 1 MHz) > 45 dB (Typical at 100 kHz) Leakage Current Line to Ground Typically < 10 mA (per phase) General Data Number of Phases 3-Phase + Protective Earth (PE) Connection Type Screw Terminals Mounting Through-hole or bracket mounting (panel mount) Operating Temperature -25 °C to +100 °C Housing Material Metal case (typically aluminum) for effective shielding and heat dissipation

More details >> Request a Quote >>
eaton
DS7-342SX081N0-N
Category Parameter Specification / Typical Value Electrical Ratings Rated Voltage 342 VAC (3~ + PE) Rated Current 81 A Frequency 50/60 Hz Test Standards Safety Standards UL 60939, IEC 60939, EN 60939 EMC Standards Designed to meet CISPR 11/32, EN 55011/55032 Filter Performance Insertion Loss > 60 dB (Typical at 1 MHz) > 45 dB (Typical at 100 kHz) Leakage Current Line to Ground Typically < 15 mA (per phase) General Data Number of Phases 3-Phase + Protective Earth (PE) Connection Type Screw Terminals Mounting Through-hole or bracket mounting (panel mount) Operating Temperature -25 °C to +100 °C Housing Material Metal case (typically aluminum) for effective shielding and heat dissipation

More details >> Request a Quote >>
eaton
DS7-340SX055NO-L
Category Parameter Specification / Typical Value Electrical Ratings Rated Voltage 340 VAC (3~ + PE) Rated Current 55 A Frequency 50/60 Hz Test Standards Safety Standards UL 60939, IEC 60939, EN 60939 EMC Standards Designed to meet CISPR 11/32, EN 55011/55032 Filter Performance Insertion Loss > 60 dB (Typical at 1 MHz) > 45 dB (Typical at 100 kHz) Leakage Current Line to Ground Typically < 10 mA (per phase) General Data Number of Phases 3-Phase + Protective Earth (PE) Connection Type Screw Terminals Mounting Through-hole or bracket mounting (panel mount) Operating Temperature -25 °C to +100 °C Housing Material Metal case (typically aluminum) for effective shielding and heat dissipation

More details >> Request a Quote >>
eaton
DS7-340SX055N0-L
Category Parameter Specification / Typical Value Electrical Ratings Rated Voltage 340 VAC (3~ + PE) Rated Current 55 A Frequency 50/60 Hz Test Standards Safety Standards UL 60939, IEC 60939, EN 60939 EMC Standards Designed to meet CISPR 11/32, EN 55011/55032 Filter Performance Insertion Loss > 60 dB (Typical at 1 MHz) > 45 dB (Typical at 100 kHz) Leakage Current Line to Ground Typically < 10 mA (per phase) General Data Number of Phases 3-Phase + Protective Earth (PE) Connection Type Screw Terminals Mounting Through-hole or bracket mounting (panel mount) Operating Temperature -25 °C to +100 °C Housing Material Metal case (typically aluminum) for effective shielding and heat dissipation

More details >> Request a Quote >>
eaton
DS7-340SX032N0-N
Category Parameter Specification / Typical Value Electrical Ratings Rated Voltage 340 VAC (3~ + PE) Rated Current 32 A Frequency 50/60 Hz Test Standards Safety Standards UL 60939, IEC 60939, EN 60939 EMC Standards Designed to meet CISPR 11/32, EN 55011/55032 Filter Performance Insertion Loss > 50 dB (Typical at 1 MHz) Leakage Current Line to Ground Typically < 5 mA (per phase) General Data Number of Phases 3-Phase + Protective Earth (PE) Connection Type Screw Terminals Mounting Through-hole or bracket mounting Operating Temperature -25 °C to +100 °C Housing Material Metal case (typically aluminum)

More details >> Request a Quote >>
eaton
ETR4-69-A
Category Parameter Specification / Typical Value Motor Protection Setting Current Range (Iᵣ) 0.63 - 1 A (This is the core protective range) Tripping Class 10A (Standard tripping time: < 10 sec at 7.2 x Iᵣ) Ambient Temperature Compensation Yes, for stable performance across a range of temperatures Electrical Characteristics Rated Operational Voltage (Uᵢ) Up to 690 V AC Utilisation Category AC-3: Squirrel cage motors Contacts Control Circuit Contacts 1 NO (97-98) - Fault Signal 1 NC (95-96) - Fault Signal Rated Thermal Current (Iᵗʰ) 9 A General Data Mounting Snap-on to compatible Eaton contactors (e.g., DILM series) Reset Mode Manual reset (Standard for safety after a trip) Status Indication Mechanical flag for trip indication Standards IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14

More details >> Request a Quote >>
eaton
ETR4-51-A
Category Parameter Specification / Typical Value Motor Protection Setting Current Range (Iᵣ) 0.15 - 0.24 A (This is the core protective range) Tripping Class 10A (Standard tripping time) Ambient Temperature Compensation Yes Electrical Characteristics Rated Operational Voltage (Uᵢ) Up to 690 V AC Utilisation Category AC-3: Squirrel cage motors Contacts Control Circuit Contacts 1 NO (97-98) - Fault Signal 1 NC (95-96) - Fault Signal Rated Thermal Current (Iᵗʰ) 9 A (Frame rating) General Data Mounting Snap-on to compatible Eaton contactors Reset Mode Manual reset (Standard for safety after a trip) Status Indication Mechanical flag for trip indication Standards IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14

More details >> Request a Quote >>
eaton
FAK-S/KC11/I
Category Parameter Specification / Typical Value Input Characteristics Input Voltage Universal AC/DC (e.g., 24-240V AC/DC) Input Type Typically voltage-sensing Output Characteristics Contact Configuration 1 CO (Changeover) / SPDT Contact Rating Typically 6A @ 250V AC / 6A @ 30V DC Utilisation Category AC-15: Control of electromagnetic loads DC-13: Control of DC solenoids Isolation & Indication Isolation Reinforced insulation between input and output circuits Status Indication LED to indicate when the input is energized and the output is active General Data Mounting 35 mm DIN Rail Connection Type Screw terminals or spring-cage terminals (depending on version) Operating Temperature -25 °C to +60 °C Standards IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14

More details >> Request a Quote >>
eaton
BW50AAG 50A
Technical Specifications Parameter Specification Manufacturer / Brand Eaton Model Number BW50AAG Series BR / BL Type Amperage Rating 50 A Number of Poles 2 Voltage Rating 120/240 VAC Frequency 50/60 Hz Interrupting Rating (AIC) 10,000 Amps Trip Type Thermal-Magnetic Mounting Style Plug-On Width (Pole Space) 1-inch per pole (2 inches total) Standards Compliance UL 489 Listed Common Trip Yes Termination Standard screw terminals Horsepower Rating Typically 2 HP @ 240V AC Torque Specification Please refer to the latest Eaton installation instructions (typically 35-50 lb-in for field wiring). Typical Applications: Electric Ranges and Ovens Air Conditioning Compressors Electric Water Heaters Subpanels / Feeder Circuits Workshops and Garages

More details >> Request a Quote >>
eaton
BW32AAG 10A
Technical Specifications) Parameter Specification Manufacturer / Brand Eaton Model Number BW32AAG Series BR / BL Type Amperage Rating 10 A Number of Poles 2 Voltage Rating 120/240 VAC Frequency 50/60 Hz Interrupting Rating (AIC) 10,000 Amps Trip Type Thermal-Magnetic Mounting Style Plug-On Width (Pole Space) 1-inch per pole (2 inches total) Standards Compliance UL 489 Listed Common Trip Yes Termination Standard screw terminals Horsepower Rating Typically 1 HP @ 240V AC Torque Specification Please refer to the latest Eaton installation instructions. Typical Applications: 240-Volt Lighting Circuits Small Appliance Circuits Control Circuits HVAC Unit Control Boards Other Dedicated 10-amp, 240-volt Loads

More details >> Request a Quote >>
1 2
··· ···