Products
Products
home
OEM Industrial IO Module ACT20X-2HAI-2SAO-P

Weidmüller ACT20X-2HAI-2SAO-P is a 2-channel intrinsically safe HART transparent signal isolator, designed for hazardous area process automation applications. It achieves galvanic isolation between intrinsically safe Ex field side and safe control side, safely transmitting 4–20mA analog current signals from Zone 0/1 hazardous areas to DCS/PLC systems in safe zones, while supporting bidirectional transparent HART protocol communication for smart transmitter parameter configuration and diagnosis

open
TEL:+86 13600179521
Mail:info@easyautomationparts.com
info@easyautomationparts.com
WhatsApp
Parameters
Request a Quote
Return to List
Technical Parameters Basic Information Model: ACT20X-2HAI-2SAO-P Order Number: 2456150000 Channel: 2 Isolated Input Channels + 2 Isolated Output Channels Mounting: Standard TS35 DIN top-hat rail Housing Width: 22.5 mm slim design Connection: Screw clamp terminal Net Weight: 212 g Power Supply Operating Voltage: 19.2 ~ 31.2 VDC (Nominal 24VDC) Power Consumption: Max 1.9 W Input Specifications (Ex Intrinsically Safe Side) Input Signal: 4 ~ 20 mA DC, active/passive loop supported HART Compatibility: Bidirectional transparent HART transmission, 0.5~2.5kHz Wire Break Diagnosis: Output signal drops below 1mA for open-circuit alarm Sensor Supply Voltage: 3.8 ~ 26 VDC Output Specifications (Safe Side) Output Signal: 4 ~ 20 mA programmable current signal Max Load Resistance: ≤ 600 Ω Signal Reverse Supported: 20~4mA reverse output optional Response Time: ≤ 5 ms Accuracy & Isolation Performance Basic Accuracy: < 0.1 % FS (Full Scale) Temperature Coefficient: < 0.01 % FS / ℃ Isolation Voltage: 2.6 kV (Input ↔ Output galvanic isolation) Overvoltage Category: II; Pollution Degree: 2 Alarm Function Fault Output: 1-channel voltage-free NC relay contact Trigger Condition: Input wire break, over-range, power failure, module fault Mechanical & Environmental Parameters Overall Dimension: 127.3 (H) × 22.5 (W) × 114.6 (D) mm Operating Temperature: -20 ℃ ~ +60 ℃ Storage Temperature: -20 ℃ ~ +85 ℃ Relative Humidity: 0 ~ 95% RH, non-condensing Protection Class: IP20 (cabinet indoor installation) Max Altitude: ≤ 2000 m Safety & Certifications Functional Safety: SIL 2 compliant (IEC 61508), SFF=80%, MTBF=177 years Hazardous Area Approval: ATEX / IECEx for Zone 0, Zone 1, Zone 2 Safety Compliance: NAMUR NE43 fault diagnosis standard Certifications: cULus (E337701), CE, DNVGL Compliance: RoHS, REACH