Technical Parameters
Basic Information
Brand: ALSTOM / Converteam
Part Number: NG4
Equivalent platform model: PRS12N04BA
Form Factor: Standard 3U slide-in rack pluggable low-voltage power supply module
Matching peripheral boards: MVTU/MVTT traction master CPU, MVAJ/MVAX/MVUA high voltage auxiliary power supply, 8197-4002/8198-4002 analog sampling boards, 8165-4004 IGBT gate drive boards, 8239-4018 digital safety I/O boards, 9510-4001 TCMS communication gateway, SIR4 safety relay isolation board
Application: European urban metro & light rail traction converter, independent battery-powered backup logic power supply, guarantees fault recording and vehicle communication functions when traction high-voltage system is shut down
Input Power Specifications
Rated input voltage: DC 110V vehicle auxiliary battery power
Wide operating input range: DC 77V ~ 137.5V
Max rated input power: 120 W
Input protection functions: Overvoltage cut-off protection, undervoltage lockout interlock, reverse polarity blocking diode, multi-stage TVS surge absorption circuit, built-in high-current input fuse
Galvanically Isolated Stabilized Output Channels
DC24V / 4.0A
Standard working power for digital I/O boards, safety relay loops, signal conditioning circuits and cabinet monitoring sensors
±15V / 1.8A
Precision reference power for high-precision analog sampling and 4–20mA temperature signal acquisition circuits
±5V / 3.0A
Core logic power for DSP traction master CPU, rack backplane communication chips and non-volatile fault storage memory
All output circuits achieve complete galvanic isolation from DC110V input side to eliminate ground loop potential difference interference
Independent hardware protection for each channel: overcurrent current limiting, short-circuit auto latch-off, over-temperature shutdown, automatic self-recovery after fault elimination
Mechanical Specifications
Overall dimension: H130 mm × W98 mm × D220 mm
PCB protection: Full acrylic conformal coating, anti-moisture, anti-corrosion, anti-dust, anti-mold
Front panel LED indicators: DC110V Input Power OK, 24V Output Normal, ±15V Output Normal, ±5V Logic Fault Alarm, Overheat Warning
Fastening structure: Anti-looseness lock buckle, maintains stable electrical contact under long-term vehicle running vibration and impact
NG4 optimization feature: Compact component layout, enhanced multi-stage EMI filter, improved heat convection for narrow confined traction cabinet installation
Railway Environmental & EU EN Compliance
Operating ambient temperature: -25 ℃ ~ +70 ℃
Storage & transport temperature: -40 ℃ ~ +85 ℃
Relative humidity: 5% ~ 95% non-condensing
Vibration test standard: IEC 61373 railway rolling stock
Shock resistance: 12g half-sine wave impact test
EMC standard: EN 50121-3-2 railway vehicle electromagnetic compatibility
Fire safety grade: EN 45545-2 HL2 low smoke, low toxicity flame retardant material