Technical Specifications
Basic Identification
Brand: Alstom Areva, later GE Grid Solutions MiCOM series
Model: MiCOM P990
Product Type: All-in-one Bay Control, Protection & Metering IED
Application: MV feeder bays, distribution transformers, railway traction substation switchgear, industrial plant power distribution
Auxiliary Power Supply
Rated supply: Dual range DC 110 V / DC 220 V universal input
Operating tolerance: 77–137.5 VDC (110V); 154–275 VDC (220V)
Typical power consumption: ≤20 W under full load
Surge withstand: Class III overvoltage category, 2kV surge pulse immunity
CT / VT Measurement Inputs
CT secondary rated: Switchable 1 A / 5 A, 50 Hz
VT rated voltage input: 100 V AC phase-to-phase
Input burden: CT < 0.7 VA per phase; VT < 1.0 VA per phase
Measurement accuracy: Class 0.5S for current, Class 0.2 for voltage, power & energy
Full Integrated Protection Functions
Overcurrent & Earth Fault Protection
Two-stage phase overcurrent: IDMT inverse curve + definite instantaneous trip
Sensitive residual earth fault two-stage protection
Thermal overload monitoring for cables & transformers
Negative sequence unbalance protection for three-phase asymmetry faults
Voltage & Frequency Protection
Overvoltage / undervoltage / voltage unbalance supervision
Overfrequency / underfrequency load shedding logic
Loss-of-mains / loss-of-voltage grid islanding detection
Supervision & Auxiliary Fault Logic
Broken CT supervision, trip circuit continuous supervision
Breaker failure protection, auto-reclose configurable sequences
Neutral voltage displacement protection for unearthed MV networks
Binary Input & Relay Output Interfaces
Binary Inputs (DI): Up to 24 channels, DC110V signal level for breaker position, interlock, blocking, remote trip signals
Relay Outputs (DO): Up to 12 forced-guided heavy-duty mechanical relays
AC-15 rating: 250 VAC, 6 A resistive / inductive load
DC-13 rating: 110 VDC, 3 A inductive trip coil load
Contact mechanical life: ≥10,000,000 cycles unloaded; electrical life ≥100,000 full rated operations
Recording & Data Storage
Event log storage: Min. 1000 time-stamped fault & alarm records with millisecond precision
Disturbance recorder: 80-cycle high-speed waveform capture for post-fault analysis
Historical trend data: Storing voltage, current, power, temperature trending curves
Non-volatile memory retains all settings & records without auxiliary power supply
Multi-Communication Interfaces
Rear RJ45 Ethernet: IEC 61850, IEC 60870-5-104, DNP3 TCP/IP
Isolated RS485 serial port: Modbus RTU, IEC 60870-5-103
Front RS232 maintenance port: Local parameter configuration, firmware upgrade
Dual redundant communication channels optional for critical traction substation applications
Mechanical & Installation
Mounting method: Standard flush panel mounting, unified industry cabinet cutout
Front panel: Backlit color graphical LCD, multi-status LED array, lockable transparent cover for tamper prevention
Wiring terminals: Rear screw-clamp terminal blocks for CT, VT, supply, DI/DO wiring
Overall dimensions: H 172 mm × W 144 mm × D 230 mm
Net weight: ~1.45 kg