Specifications
Rated Input Voltage: 1-phase / 3-phase 110~230 VAC, frequency 47~63 Hz
Control Power Supply: 24 VDC
Continuous Output Current: 3 A (RMS)
Peak Output Current: 18.6 A (RMS, sustainable for 500ms, 300% overload)
Rated Input Capacity: 0.88~1.4 kVA; Rated Output Capacity: 0.7~1.1 kVA
PWM Switching Frequency: 8 kHz
DC Bus Overvoltage Protection Point: 430 VDC
DC Bus Undervoltage Protection Point: 90 VDC
Safety Function: Integrated STO Safe Torque Off (SIL2 compliant)
Control Command Mode: SERCOS III bus control, ±10V analog command, pulse/direction, electronic gear following
Built-in Protection: Overcurrent, overvoltage, undervoltage, overtemperature, short-circuit, encoder fault, overspeed multi-level safety protection
Communication & Feedback Configuration
Main Fieldbus Interface: SERCOS III high-speed real-time motion bus
Debug Interface: RS232 serial port, matched with MOTIONLINK software for parameter configuration, online debugging, fault diagnosis and firmware upgrade
Digital I/O: Multi-channel configurable isolated input & output terminals for enable interlock, fault alarm, homing, positioning completion signal
Supported Feedback Types: Resolver, TTL incremental encoder, 1Vpp sine/cosine encoder, Hiperface encoder
Max Encoder Input Frequency: 3 MHz
Mechanical & Environmental Specifications
Protection Class: IP20
Mounting Method: Vertical cabinet wall-mounted installation
Overall Dimensions: 163 mm × 67.3 mm × 36.6 mm
Net Weight: Approx 1.61 kg
Operating Ambient Temperature: 0 ℃ ~ +45 ℃ (power derating required above 40℃)
Storage & Transportation Temperature: -20 ℃ ~ +70 ℃
Ambient Humidity: 5%~95% RH, non-condensing, free of corrosive gas and conductive dust
Altitude Derating: Derate 5% per 1000m above 1000m altitude
Certifications: CE, UL, cUL compliant