Products
Products
home
H3CR-G8EL Safety Light Curtain | F3SJ Series Industrial Safety Sensor

The OMRON H3CR-G8EL is a DIN 48 × 48-mm Star-Delta Timer with an instantaneous output contact , designed for reduced-voltage starting of three-phase induction motors . It is an 8-pin socket-mounted timer that provides a complete timing solution for Star-Delta motor control.

open
TEL:+86 13600179521
Mail:info@easyautomationparts.com
info@easyautomationparts.com
WhatsApp
Parameters
Request a Quote
Return to List
Specifications Specification Parameter / Value Product Type Solid-state Timer / Star-Delta Timer Series H3CR-G Model H3CR-G8EL (8-pin, with instantaneous output) Operating Mode Star-Delta Operating/Reset Method Time-limit operation / Self-reset Connection Type 8-pin Round Socket (Octal) – special terminal arrangement Mounting Type Socketable (DIN track, surface, or flush mounting) Ratings Specification Parameter / Value Rated Supply Voltage Options 100 to 120 VAC (50/60 Hz) / 200 to 240 VAC (50/60 Hz) Operating Voltage Range 85% to 110% of rated supply voltage Power Consumption (100-120V) Approx. 6 VA (2.6 W) at 120 VAC Power Consumption (200-240V) Approx. 12 VA (3.0 W) at 240 VAC Reset Voltage 10% max. of rated supply voltage Recommended Fuse 0216005 (250 VAC, 5A) manufactured by Littelfuse Output Specifications Specification Parameter / Value Output Configuration 3 x SPST-NO (3 Form A) Output Assignment • Time-limit (Star) – SPST-NO (Star operation circuit) • Time-limit (Delta) – SPST-NO (Delta operation circuit) • Instantaneous – SPST-NO Rated Load 5 A at 250 VAC / 30 VDC (resistive load, cosφ = 1) Minimum Applicable Load 10 mA at 5 VDC (P level, reference value) Rated Insulation Voltage 250 V Rated impulse withstand voltage 4 kV (at 240 VAC, altitude: 2,000 m max.) Conditional short-circuit current 1000 A Contact Material Ag-alloy Timing Specifications Specification Parameter / Value Number of Time Ranges 4 (Switch selectable) Star Operation Time Ranges Scale 6: 0.5–6 s Scale 12: 1–12 s Scale 60: 5–60 s Scale 120: 10–120 s Star-Delta Transfer Time Programmable: 0.05 s, 0.1 s, 0.25 s, 0.5 s, 0.75 s, or 1.0 s Accuracy of Operating Time ±0.2% FS max. Setting Error ±5% FS ±50 ms max. Accuracy of Star-Delta Transfer Time ±25% FS +5 ms max. Influence of Voltage ±0.2% FS max. Influence of Temperature ±1% FS max. Power Reset Minimum power-opening time: 0.5 s Environmental & Mechanical Specification Parameter / Value Ambient Temperature (Operating) -10 to 55°C (with no icing) Ambient Temperature (Storage) -25 to 65°C (with no icing) Ambient Humidity (Operating) 35% to 85% Degree of Protection IP40 (panel surface) Case Color Light Gray (Munsell 5Y7/1) Weight Approx. 130 g