Products
Products
home
B&R Automation X67 Bus Controller X67 System X67BC4321-10 IP67 I/O Module

The B&R X67BC4321-10 is an industrial CANopen bus controller designed for the B&R X67 distributed I/O system.

open
TEL:+86 13600179521
Mail:info@easyautomationparts.com
info@easyautomationparts.com
WhatsApp
Parameters
Request a Quote
Return to List
Technical Parameters: Brand: B&R (Bernecker + Rainer) Model: X67BC4321-10 Product Type: CANopen Bus Controller Product Series: X67 System Fieldbus Interface: CANopen Number of Digital Channels: 8 Channel Configuration: Software-configurable as Inputs or Outputs Nominal Voltage: 24 VDC Input Voltage Range: 18–30 VDC Channel-to-Bus Isolation Voltage: 500 V RMS B&R ID Code (Bus Controller): 0xA90D B&R ID Code (Internal I/O Module): 0xB528 Communication Parameters: Fieldbus Protocol: CANopen Fieldbus Connector: M12, A-coded X2X Link Connector: M12, B-coded Maximum CANopen Transmission Distance: 1000 m Maximum CANopen Baud Rate: 1 Mbit/s Baud Rate Detection: Automatic Minimum X2X Link Cycle Time: 500 μs Maximum CANopen PDO Configuration: 32 Rx PDOs / 32 Tx PDOs Connected X2X Link Modules: Up to 253 Digital Input Parameters: Input Type: Sink Input Voltage: 18–30 VDC Input Current at 24 VDC: Typical 4 mA Input Resistance: Typical 6 kΩ Input Filter: ≤10 μs (Channels 1–4) Input Filter: ≤70 μs (Channels 5–8) Software Filter: Configurable from 0 to 25 ms Switching Threshold – Low: Less than 5 VDC Switching Threshold – High: Greater than 15 VDC Input Functions: Event Counting and Gate Time Measurement Event Counters: 2 Maximum Event Counting Frequency: 50 kHz Counter Resolution: 16-bit Digital Output Parameters: Output Type: Current-Sourcing FET Nominal Output Voltage: 24 VDC Nominal Output Current: 0.5 A per channel Total Nominal Output Current: 4 A Maximum Resistive Load Switching Frequency: 100 Hz Switching Delay: Less than 400 μs Output Protection: Short-Circuit and Overcurrent Protection Residual Voltage: Less than 0.3 V at 0.5 A Power Supply Parameters: I/O Supply Voltage: 24 VDC Permissible Voltage Range: 18–30 VDC X2X Link Power Output: 3 W Sensor/Actuator Supply Current: Maximum 0.5 A Maximum Sensor/Actuator Power: 12 W Short-Circuit Protection: Yes Reverse Polarity Protection: Yes Fieldbus Power Consumption: 2 W Internal I/O Power Consumption: 2.1 W Mechanical Parameters: Protection Rating: IP67 Width: 53 mm Height: 85 mm Depth: 42 mm Weight: Approx. 200 g Fieldbus Connector: M12 I/O Connectors: 8 × M8, 3-pin I/O Power Connector: M8, 4-pin Mounting Orientation: Any Environmental Parameters: Operating Temperature: -25 to +60°C Storage Temperature: -40 to +85°C Transport Temperature: -40 to +85°C