Products
Products
home
B&R Automation X20 Modular I/O Module X20 System X20AP3132 PLC I/O Module

The B&R X20AP3132 is a three-phase power and energy metering module designed for the B&R X20 modular I/O system.

open
TEL:+86 13600179521
Mail:info@easyautomationparts.com
info@easyautomationparts.com
WhatsApp
Parameters
Request a Quote
Return to List
Technical Parameters Brand: B&R Model: X20AP3132 Product Type: 3-Phase Power and Energy Metering Module Product Series: X20 B&R ID Code: 0xE7C0 Number of Voltage Phases: 3 Maximum Phase-to-Phase Voltage: 480 VAC Maximum Phase-to-Neutral Voltage: 277 VAC Voltage Input Impedance: 1.68 MΩ Voltage Measurement Category: CAT II Rated Frequency: 50 / 60 Hz Frequency Measurement Range: 45–65 Hz Frequency Resolution: 0.01 Hz Number of Current Inputs: 4 AC inputs Current Transformer Secondary Rating: 5 A Configurable Primary Current: 65 A directly; higher values configurable through application conversion Maximum Measuring Current: 5 A Maximum Overload Current: 8 × rated current for 0.5 s Current Input Load: 20 mΩ Voltage Resolution: 10 mV Current Resolution: 1 mA (based on primary current) RMS Voltage Accuracy: ±0.65% RMS Current Accuracy: ±0.65% Power Measurement Accuracy: ±0.80% Active Energy Accuracy: ±0.40% Reactive Energy Accuracy: ±0.50% Frequency / Power Factor / Phase Angle Accuracy: ±0.50% Bus Power Consumption: 0.45–0.85 W (depending on hardware revision) Additional Module Power Dissipation: 2 W Electrical Isolation: Measurement channels isolated from bus; channels not isolated from each other Protection Rating: IP20 Operating Temperature: -25 to +60°C (horizontal mounting); -25 to +50°C (vertical mounting) Storage Temperature: -40 to +85°C Relative Humidity: 5–95%, non-condensing Certifications: CE, UKCA, cULus, ATEX Zone 2Technical Parameters Brand: B&R Model: X20AP3132 Product Type: 3-Phase Power and Energy Metering Module Product Series: X20 B&R ID Code: 0xE7C0 Number of Voltage Phases: 3 Maximum Phase-to-Phase Voltage: 480 VAC Maximum Phase-to-Neutral Voltage: 277 VAC Voltage Input Impedance: 1.68 MΩ Voltage Measurement Category: CAT II Rated Frequency: 50 / 60 Hz Frequency Measurement Range: 45–65 Hz Frequency Resolution: 0.01 Hz Number of Current Inputs: 4 AC inputs Current Transformer Secondary Rating: 5 A Configurable Primary Current: 65 A directly; higher values configurable through application conversion Maximum Measuring Current: 5 A Maximum Overload Current: 8 × rated current for 0.5 s Current Input Load: 20 mΩ Voltage Resolution: 10 mV Current Resolution: 1 mA (based on primary current) RMS Voltage Accuracy: ±0.65% RMS Current Accuracy: ±0.65% Power Measurement Accuracy: ±0.80% Active Energy Accuracy: ±0.40% Reactive Energy Accuracy: ±0.50% Frequency / Power Factor / Phase Angle Accuracy: ±0.50% Bus Power Consumption: 0.45–0.85 W (depending on hardware revision) Additional Module Power Dissipation: 2 W Electrical Isolation: Measurement channels isolated from bus; channels not isolated from each other Protection Rating: IP20 Operating Temperature: -25 to +60°C (horizontal mounting); -25 to +50°C (vertical mounting) Storage Temperature: -40 to +85°C Relative Humidity: 5–95%, non-condensing Certifications: CE, UKCA, cULus, ATEX Zone 2