A16L-TGA-24D-1 Safety Light Curtain | F3SJ Series Industrial Safety Sensor

The Omron A16L-TGA-24D-1 is a φ16 mm illuminated pushbutton switch from the A16 series. It features a round projection-type green actuator and uses an alternate (push-on/push-off) action, which maintains its state after being pressed, unlike momentary switches .

open
TEL:+86 13600179521
Mail:info@easyautomationparts.com
info@easyautomationparts.com
WhatsApp
Parameters
Request a Quote
Return to List
Key Specifications Parameter Value/Description Manufacturer Omron Automation and Safety Part Number A16L-TGA-24D-1 Series A16 Type Illuminated Pushbutton Switch Mounting Hole Diameter 16 mm Actuator Type Round projection type Actuator Color Green Illumination LED, Green Illumination Voltage 24 VAC/VDC (±5%) Contact Configuration SPDT (1c / Single Pole Double Throw) Switch Function Alternate (On-On / Push-on/Push-off) Termination Type Solder terminal / Quick-connect (#110/t=0.5) Degree of Protection IP40 Contact Ratings Parameter Value Rated Load (AC) 5 A at 125 VAC / 3 A at 250 VAC (resistive load) Rated Load (DC) 3 A at 30 VDC (resistive load) Minimum Applicable Load 5 VDC 1 mA (resistive load) Lamp/LED Specifications Parameter Value Lamp Type LED (built-in) Lamp Color Green Rated Voltage 24 VAC/VDC Operating Voltage 24 VAC/VDC ±5% Rated Current (Lamp) 8 mA Mechanical Specifications Parameter Value Operating Force (OF) 4.41 N max. Release Force (RF) 0.29 N min. Pretravel (PT) 2.5 mm max. Total Travel (TT) Approx. 3 mm Lock Travel Alternate (LTA) 0.5 mm min. Electrical Life 100,000 operations min. (at rated load) Mechanical Life 200,000 operations min. Permissible Operating Freq. (Electrical) 20 operations/min max. Permissible Operating Freq. (Mechanical) 60 operations/min max. Insulation & Dielectric Strength Parameter Value Insulation Resistance 100 MΩ min. (at 500 VDC) Dielectric Strength (Same polarity terminals) 1,000 VAC, 50/60 Hz for 1 min Dielectric Strength (Different polarity terminals) 2,000 VAC, 50/60 Hz for 1 min Dielectric Strength (Terminal to ground) 2,000 VAC, 50/60 Hz for 1 min Dielectric Strength (Lamp terminals) 1,000 VAC, 50/60 Hz for 1 min (without LED) Environmental Specifications Parameter Value Operating Temperature -10°C to 55°C (with no freezing or condensation) Storage Temperature -25°C to 65°C Operating Humidity 35% to 85% Vibration Resistance (Malfunction) 10 to 55 Hz, 1.5 mm double amplitude (malfunction: 1 ms max.) Shock Resistance (Destruction) 500 m/s² max. Shock Resistance (Malfunction) 150 m/s² max. Physical Specifications Parameter Value Panel Cutout Circular - 16.00 mm diameter Body Dimensions (W × H) 18 × 18 mm Depth Behind Panel 30.6 mm (miniature design) Protection Class Class II Pollution Degree 3 (IEC60947-5-1) PTI (Tracking characteristic) 175 Safety Standards CE, UL, cUL, TUV, CCC