Parameter Specification
Product Model EACRO420SC
Product Line Eaton EASY AC Soft Starter
Rated Motor Power 20 HP (15 kW) @ 480V AC
Rated Current 42 A (This is inferred from the model number "420", where 42 is the amperage)
Supply Voltage 200-480 V AC, 50/60 Hz
Control Method Voltage ramp control with built-in EnergySaver function (improves efficiency at partial load)
Key Features
Built-in Bypass Contactor: Reduces heat and energy consumption after start-up.
Adjustable Start Voltage / Torque
Adjustable Ramp Time
Adjustable Stopping Mode (Coast, Soft stop)
Integrated Overload Protection
Protection Functions
Overload
Phase Loss / Imbalance
Overcurrent
Heatsink Overtemperature
Control Connections Screw terminals for Start/Stop control and status relays.
Mounting DIN Rail Mount (Standard 35 mm)
Standards Compliance UL Listed, cULus, CE Marked
Parameter Specification / Inference
Product Model 13104RQD007
Product Line Cutler-Hammer by Eaton
Product Type Push Button Operator
Operator Color Green
Operator Shape Rectangular
Mounting Style Quick-Disconnect (QD) - Front mounting
Contact Block Compatibility Designed to mate with standard Eaton/Cutler-Hammer contact blocks (e.g., 1NO, 1NC, 1NO/1NC). Note: Contacts are sold separately.
Lens Legend Typically unmarked or with a standard "I" (for On). Custom legends may be available.
Enclosure Rating NEMA 4X, 13; IP65 (Oil-tight, Dust-tight, Water-resistant)
Material Thermoset plastic or similar durable material.
Panel Cutout Designed for a specific rectangular cutout.
Standards Compliance UL Listed, cULus, CE
Parameter Specification / Inference
Product Model EEA-PAM-533-A-33
Product Type Pre-assembled Power Analysis & Monitoring Module
Rated Voltage Likely 208/240 V AC (inferred from "-33" suffix, common in 3-phase Wye/Delta configurations)
Input Current Dependent on the integrated Current Transformers (CTs). The "533" may specify the CT ratio (e.g., for a 500:5 A or similar CT).
Monitored Parameters
Voltage (Line-to-Line, Line-to-Neutral)
Current
Power (kW, kVA, kVAR)
Energy (kWh)
Frequency
Power Factor
Communication Interface Likely RS-485 with a standard protocol like Modbus RTU.
Alarm Outputs Typically includes dry contact relays for alarms (e.g., over-voltage, under-voltage, over-current).
Mounting Designed for internal mounting within a specific Eaton enclosure or chassis.
Compliance UL, CE, and other regional standards applicable to the host equipment.
Parameter Specification
Product Model NZM2-XSH-12-84-NA
Product Line Eaton NZM MCCB
Frame Size NZM2
Rated Current (In) 125 A (Set by the "12" rating plug)
Number of Poles 3
Rated Operational Voltage (Ue) 600 V AC
Trip Unit Type Electronic (XSH)
Protection Functions
L - Long-Time (Overload)
S - Short-Time (Short-Circuit)
I - Instantaneous
G - Ground Fault
All are adjustable.
Rated Breaking Capacity (Icu) High (e.g., 65 kA @ 480V AC or similar). Must be verified from datasheet.
Communication Capability Yes, typically ready for communication modules (e.g., for Modbus, PROFIBUS).
Mounting Fixed or Plug-in (specific type to be confirmed)
Standards Compliance UL 489, CSA C22.2 No. 5 (for the NA market)
Parameter Specification / Inference
Product Model DAC-4-04-010-A1A1-HE-12-R0
Product Line Eaton DAC Soft Starter
Rated Operational Voltage 400V class (e.g., 380-480V AC)
Rated Current 104 A (This is the maximum continuous current rating of the soft starter itself)
Rated Motor Power Approximately 55 kW / 75 HP @ 400V (基于 104A 电流推断)
Supply Voltage Defined by A1A1 (e.g., 100-120V AC, 50/60 Hz for control circuits)
Key Features
Special Feature Heat Sink Extender (-HE) for improved thermal performance.
Control Interface Digital display and keypad (language specified by -12).
Protection Functions
Parameter Specification / Inference
Product Model E58-30DPS280-ELPB
Product Line Eaton E58 Building Automation Sensors
Sensor Type Differential Pressure Transmitter
Pressure Range 0 to 2.80 in. w.c. (约 0 to 697 Pa)
Output Signal 0-10 V DC (2-wire)
Power Supply Typically 15-35 V DC
Accuracy Typically ±1% of full scale or better
Response Time Typically < 1 second
Port Connections Likely two pressure ports (High and Low) for tubing connections.
Electrical Connection 1/2" NPT conduit entry (inferred from ELPB)
Mounting Printed Circuit Board (PCB) Mount (inferred from ELPB)
Operating Temperature 0°C to 50°C (32°F to 122°F) - typical for indoor applications
Media Air and non-corrosive gases
Parameter Specification / Inference
Product Model ES4P-221-DRXD1
Product Line Eaton ES4P Advanced Pressure Sensors
Sensor Type Differential Pressure Transmitter
Pressure Range Field-Selectable (e.g., 0-0.25 in. w.c., 0-1.0 in. w.c., and others)
Averaging Function Dual-Point Averaging (D)
Output Signal Programmable: 0-10 V DC or 4-20 mA (RX)
Power Supply Typically 15-35 V DC (for 4-20mA) or 12-35 V DC (for 0-10V)
Accuracy High, typically ±1% of reading or ±0.5% of full scale (depending on range)
Response Time User-adjustable
Port Connections Two pressure ports (High and Low) for tubing. The dual averaging function requires external tubing manifolds.
Electrical Connection 1/2" NPT conduit entry
Mounting Surface mount or duct mount
Operating Temperature 0°C to 50°C (32°F to 122°F)
Media Air and non-corrosive gases
Parameter Specification / Inference
Product Model LS-S02-24DMT-ZBZ/X
Product Type Inductive Proximity Sensor
Housing Shape/Size Cylindrical, M12 x 1 thread
Detection Type Shielded (Flush-mountable)
Sensing Distance 2 mm (nominal, for M12 size)
Supply Voltage 10-30 V DC
Output Type PNP (Sourcing)
Output Configuration Normally Open (NO)
Connection Pre-wired Cable (Specific length, e.g., 2 meters, to be verified)
Current Rating Typically ≤ 200 mA
Switching Frequency Typically 500 Hz
Housing Material Nickel-plated brass or stainless steel
Protection Rating IP67
Standard Target 12x12x1 mm (Fe 360)
Compliance CE
Parameter Specification
Product Model MTL5517
Product Line Eaton MTL Signal Conditioners & Isolators
Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area.
Output Signal Two independent, isolated 4-20 mA DC signals.
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (Example values, MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Compliance & Certifications ATEX, IECEx, FM, CSA, NEPSI, etc. (Specific certifications depend on the product suffix).
Parameter Specification / Inference
Product Model DPS2-20VF-020
Product Line Eaton DPS2 Digital Pressure Sensors
Sensor Type Digital Differential Pressure Transmitter
Pressure Range 0 to 2.0 in. w.c. (约 0 to 500 Pa)
Output Signal 0-10 V DC (2-wire)
Power Supply Typically 15-35 V DC
Accuracy Typically ±2% of reading or ±1% of full scale
Display Often includes a digital LCD display for local readout of pressure, velocity, and temperature.
Velocity Measurement Yes, can directly display air velocity (FPM or m/s) based on pressure input.
Response Time User-adjustable
Port Connections Two pressure ports (High and Low) for 1/4" OD tubing.
Electrical Connection Terminal block or pre-wired leads (to be confirmed)
Mounting Surface mount, duct mount, or 1/2" NPT conduit mount (depending on variant)
Operating Temperature 0°C to 50°C (32°F to 122°F)
Media Air and non-corrosive gases