Parameter Specification
Manufacturer Eaton
Model Number SV1-10-4-00
Product Line SV1 Safety Switches
Rated Current 30 Amps
Rated Voltage (AC) 240V AC / 480V AC
Electrical Poles 3-Pole (3-Phase)
Type Non-Fusible (Safety Switch Disconnect)
HP Rating 5 HP @ 240V AC; 10 HP @ 480V AC (Typical for this rating, confirm with datasheet)
Enclosure Requirement Designed to be mounted in a suitable enclosure (NEMA 1, 3R, 12, etc.)
Operation Manual Rotary Handle
Status Indication Visible Blade (ON/OFF visible)
Safety Standards UL 98, CSA C22.2
Common Applications Industrial control panels, motor disconnects, HVAC systems, machinery power isolation.
Parameter Specification
Manufacturer Eaton (Axiom Series)
Model Number DGMFN-5-Y-A2W-B2W-30
Product Type 5/2 Solenoid Operated Directional Control Valve
Ports 5
Positions 2 (5/2 Way)
Actuation Type Single Solenoid, Spring Return
Operator Single Solenoid
Voltage 24V DC (as indicated by the "-30" suffix)
Hazardous Location Rating UL Listed for Class I, Division 1, Groups A, B, C, D; Class II, Division 1, Groups E, F, G; Class III.
Enclosure Rating NEMA 4X (Weatherproof & Corrosion-Resistant) / IP67 (Dust-tight and Immersion resistant up to 1m)
Port Size 1/4" NPT (Common for this series, but verify with datasheet)
Operating Pressure Range Typical for this type: 30 to 120 PSI (Please consult the official datasheet for exact values)
Media Compressed Air (Lubricated or Non-Lubricated)
Body Material Die-cast Zinc (with corrosion-resistant coating)
Seal Material Buna-N (Nitrile) - Standard
Coil Class Class F (155°C)
Conduit Hubs Two 1/2" NPT (Standard for explosion-proof enclosures)
Parameter Specification
Manufacturer Eaton
Model Number 6041615-001
Product Name Maintenance Bypass Switch Assembly
Compatible UPS Series Eaton 93PM, 9PX
Rated Current 30 A
Rated Voltage 250 VAC
Electrical Poles 3-Pole (L1, L2, L3, N, G)
Switch Type Rotary Cam Switch
Switch Positions LINE - BYPASS - OFF
Wiring Hardwired (pre-assembled terminal block)
Safety Standards UL, cUL Listed
Primary Function To safely bypass the UPS for maintenance without dropping the critical load.
Typical Use Case Service, repair, or replacement of the connected UPS while keeping the downstream equipment powered.
Parameter Value / Description
Product Name Eaton DGMDC 3 Y PK 41
Type / Class Type 2 (Class II) Surge Protective Device (SPD)
Rated Voltage 400 V / 230 V AC
Nominal System Voltage 230/400 V AC
Network Configuration 3-Phase + N (Neutral) + PE (Earth)
SPD Circuit Configuration 3+1
Max. Continuous Operating Voltage Uc 335 V L-N / 335 V L-L
Voltage Protection Level Up (at In) ≤ 1.5 kV
Nominal Discharge Current In (8/20 µs) 20 kA per mode
Max. Discharge Current Imax (8/20 µs) 40 kA per mode
Impulse Current Iimp (10/350 µs) Not typically specified for Type 2; this is a Type 1 parameter.
Short-Circuit Current Rating (SCCR) 50 kA (according to UL 1449 4th Ed.)
Backup Fuse Recommendation 160 A gG / gL (or according to local regulations)
Response Time < 25 ns
Status Indication Visual (Green/Red window)
Remote Signaling Contact Yes, typically 1 changeover (CO) contact (e.g., for connection to a building management system)
Connection / Cross-Section 35 mm² flexible cable or 25 mm² solid cable
Mounting Plug-in module on 35 mm DIN rail
Standards Compliance IEC 61643-11, EN 61643-11, UL 1449 (4th Edition)
IP Protection Degree IP20
Operating Temperature -40 °C to +80 °C
Module Replacement Yes, with removable cartridge (PK 41)
Parameter Value / Description
Product Name Eaton C-175-F-11-JA-J
Product Line Eaton M22-D Series
Type Illuminated Push Button (Momentary Action)
Lens Color Green
Contact Configuration 1 Normally Open (NO) Contact
Mounting Diameter 22 mm
Voltage Rating (Light) Depending on the lamp/LED version. Requires cross-referencing the specific "F-11" actuator code. Common voltages are 24V, 110V, 230V AC/DC.
Current Rating (Contacts) Typically 10 A at 250 V AC / 6 A at 400 V AC
Electrical Life Typically > 1,000,000 mechanical operations (load-dependent)
Mechanical Life Typically > 5,000,000 operations
Degree of Protection Front side: IP66 (Dust-tight and protected against powerful water jets)
Rear side (terminals): IP20 (Protected against touch by fingers)
Connection Type Screw Clamp Terminals
Material (Actuator) Thermoplastic (Polyamide)
Operating Temperature -25 °C to +70 °C
Standards Compliance IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14
Parameter Value / Description
Product Name Eaton RG-3FK1-30-JA
Product Line Eaton RG Series Signal Towers
Type Multi-Stack LED Signal Tower / Tower Light
Number of Levels / Stories 5
Standard Color Sequence Green - Yellow - Red - Blue - White (from top to bottom)
Light Source High-Intensity LEDs
Supply Voltage 24 V DC (This is a common voltage for this series; please verify in specific datasheets)
Power Consumption Approx. 2.5 W per segment (approx. 12.5 W total for all 5 segments)
Lens Material Polycarbonate
Degree of Protection IP65 (Front and body)
Mounting Via M30 mounting thread (The "-30-" in the part number indicates this)
Connection Type Pre-wired cable or connector (specific type and length may vary; often a 2-meter cable)
Switching Each segment requires a separate DC voltage signal to activate (e.g., PLC digital output).
Operating Temperature -25 °C to +55 °C
Storage Temperature -30 °C to +70 °C
Standards Compliance IEC/EN 60529, UL 508, CSA C22.2 No. 14
Parameter Value / Description
Product Name Eaton TGM PC-3-ABK-BAK-50
Product Line Eaton TGM Series (Heavy-Duty Limit Switches)
Type Heavy-Duty Limit Switch with Maintained Contact Action
Actuator Type Side Rotary Lever (with roller)
Contact Configuration 1 Normally Open (NO) + 1 Normally Closed (NC) (This is the standard for "PC-3" series)
Rated Operating Current 10 A at 600 V AC / 0.5 A at 600 V AC (for DC voltages, please check datasheet)
Rated Insulation Voltage 600 V
Electrical Life 1,000,000 operations (at rated load)
Mechanical Life 10,000,000 operations
Degree of Protection IP65 (Dust-tight and protected against water jets)
Electrical Connection Screw Clamp Terminals
Housing Material Metal (typically die-cast zinc)
Operating Temperature -25 °C to +85 °C (depending on seal material)
Actuator Travel Approximately 12° (for this side rotary lever type)
Operating Force Defined by the lever length and spring mechanism.
Standards Compliance IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14
Parameter Value / Description
Product Name Eaton DGMPC-5-ABN-BAN-30
Product Line Eaton D4B / D4C Series (Heavy-Duty Limit Switches)
Type Heavy-Duty Limit Switch with Maintained Contact Action
Actuator Type Top Push Plunger with Roller
Contact Configuration 2 Normally Open (NO) Contacts (This is the standard configuration for the "PC-5" contact block)
Rated Operating Current 10 A at 600 V AC
Rated Insulation Voltage 600 V
Electrical Life 1,000,000 operations (at rated load)
Mechanical Life 10,000,000 operations
Degree of Protection IP65 (Dust-tight and protected against water jets)
Electrical Connection Screw Clamp Terminals
Housing Material Metal (Die-cast zinc)
Operating Temperature -25 °C to +85 °C (depending on seal material)
Pretravel The distance the plunger moves from its free position to the operating point. (Specific value requires datasheet, e.g., ~4.8mm).
Overtravel The distance the plunger can travel beyond the operating point. (Specific value requires datasheet).
Operating Force The force required to actuate the plunger (Specific value requires datasheet, e.g., ~3.5 N).
Reset Force The force exerted by the internal spring to return the plunger.
Standards Compliance IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14
Parameter Specification Notes
Series DGMDC-5
Output Power 30 W Continuous
Input Voltage (Vin) 4.5 - 5.5 VDC Wide Range
Output Voltage (Vout) 13.8 VDC Nominal
Output Current (Iout) Up to 2.17 A At full load
Efficiency Typically 89% At nominal input, full load
Isolation 1500 VDC Input to Output
Input-Output Ripple & Noise < 50 mVp-p Typical, 20MHz bandwidth
Line Regulation ±0.5% For full input range change
Load Regulation ±0.5% From 10% to 100% load
Operating Temperature -40°C to +100°C With derating above ~85°C
Storage Temperature -55°C to +105°C
Package / Mounting Through-Hole (Pin-in-Paste) "TN" Style
Dimensions (L x W x H) Approximately 33.0 x 22.6 x 10.2 mm
Safety Standards UL/EN/IEC 60950-1 Or equivalent
EMC Complies with EN 55032 (FCC Part 15) Class B Typically with external filter
Parameter Specification Notes / Explanation
Model Series DG4V
Valve Size 03 CETOP 3, NFPA D01
Mounting Interface ISO 4401-03 NFPA D01, H7 Option
Number of Ports 4 (P, T, A, B)
Number of Positions 3
Actuation Type Solenoid Operated, Hydraulic Pilot Requires pilot pressure
Solenoid Type Wet Armature DC
Maximum Operating Pressure 350 bar (5,000 psi)
Maximum Flow Capacity ~ 45 L/min (12 US gpm) Dependent on spool type and pressure drop
Pilot Pressure Range 17 - 35 bar (250 - 500 psi) minimum Required for spool shifting
Internal Pilot Supply From 'P' port
Return Spring M Spring-centered to neutral position
Manual Override U With manual override (standard)
Seal Material Standard: Nitrile (Buna-N) Optional Viton available