The Schneider Electric Acti 9 iEZ EZD160E is a three-pole electronic circuit breaker built on a 160A frame, with its electronic trip unit configured to provide protection for a 125A load. Equipped with a standard E-type electronic trip unit, it offers fully adjustable and precise protection against overloads and short-circuits.
The Schneider Electric Acti 9 iEZ EZD250E is a three-pole electronic circuit breaker built on a 250A frame, with its electronic trip unit configured to provide protection for a 200A load. Equipped with a standard E-type electronic trip unit, it offers fully adjustable and precise protection against overloads and short-circuits.
The Schneider Electric Acti 9 iEZ EZD250E is a three-pole electronic circuit breaker built on a 250A frame, with its electronic trip unit configured to provide protection for a 200A load. Equipped with a standard E-type electronic trip unit, it offers fully adjustable and precise protection against overloads and short-circuits. This configuration is ideal for applications where the load current is 200A, but the robustness, higher breaking capacity, or future scalability of a 250A frame is desired or required
The Schneider Electric Acti 9 iEZ EZD250E is a three-pole, 250A electronic circuit breaker from the advanced Acti 9 iEZ range. It is equipped with a standard E-type electronic trip unit, providing fully adjustable overload and short-circuit protection.
Product Type Gauge Pressure Transmitter
Measurement Principle Advanced sensor (e.g., Silicon Resonant)
Output Signal 4-20 mA analog output with HART® Protocol
Accuracy High, typically ±0.075% of span
Pressure Range (URL) Example: 0-1600 kPa (based on code J)
Process Connection Flush-mounted diaphragm (based on code M)
Wetted Parts Material 316L Stainless Steel (based on code A)
Power Supply 2-wire, 12-45 VDC (loop-powered)
Operating Temperature -40°C to +85°C (ambient)
Protection Rating NEMA 4X / IP67
Product Type Compact Magnetic Flowmeter (Integrated Transmitter and Tube)
Measurement Principle Faraday's Law of Electromagnetic Induction
Measured Media Electrically conductive liquids (typically with a conductivity > 5 μS/cm)
Line Size 3-inch (DN80), based on code J
Liner Material PTFE (Teflon®), based on code 1
Electrode Material 316L Stainless Steel, based on code F
Accuracy Typical: ±0.5% of rate
Output Signal 4-20 mA analog, pulse/frequency, typically with HART® Protocol
Power Supply 100-240 VAC or 24 VDC (dependent on specific order code)
Protection Rating Typically NEMA 4X / IP67 for field mounting
Model Number P0914LV
Product Type Gauge Pressure Transmitter
Pressure Type Gauge Pressure (pressure relative to atmospheric pressure)
Sensor Technology Advanced high-stability sensor (e.g., silicon resonant or capacitive)
Output Signal 4-20 mA analog output with HART® Protocol for digital communication.
Accuracy High accuracy. For low-pressure "LV" models, this is often ±0.075% of the Upper Range Limit (URL) or calibrated span.
Pressure Range (URL) The "LV" code is critical and typically indicates a low pressure range. The "14" in P0914LV often correlates to a specific range, such as 0-14 kPa (0-2 psi, 0-56 inches of water column).
Process Connection Low-pressure ports, often 1/4" NPT or similar, suitable for low-pressure gases.
Wetted Parts Material 316L Stainless Steel is standard.
Power Supply Standard 2-wire, 12-45 VDC loop-powered operation.
Operating Temperature Ambient: -40°C to +85°C (-40°F to 185°F). Process: Dependent on seal options.
Protection Rating NEMA 4X / IP67 (weatherproof and corrosion-resistant).
Product Type Rack-mounted Intelligent Pressure Module
Integrated System Foxboro I/A Series DCS
Measurement Type Differential Pressure (DP)
Typical Range (URL) Example: 0-400 inH₂O (approx. 0-100 kPa) - specific to the H code.
Accuracy Very high, typically better than ±0.1% of span.
Output Signal Digital communication directly to the I/A Series controller via the system's backplane or proprietary bus.
Power Supply Powered via the I/A Series rack backplane.
Process Connection External wiring terminals for connecting wires from the field (e.g., from a remote seal or impulse lines).
Operating Temperature Designed for a controlled cabinet environment.
Primary Application Flow Measurement (with primary elements like orifice plates) and Level Measurement.
Model Number AD207AU
Function Type Dual-Channel Analog Signal Isolator / Converter
Input Signal According to Foxboro's naming convention, "A" typically stands for a DC Current Input (e.g., 4-20 mA).
Output Signal According to Foxboro's naming convention, "U" typically stands for a DC Voltage Output (e.g., 1-5 VDC, 0-10 VDC).
Number of Channels 2 independent channels (as indicated by the "AD207" base model).
Power Supply Requires an external power source, typically 24 VDC.
Isolation Channel-to-channel isolation and channel-to-power supply isolation (typically 1500 VAC).
Accuracy High typical accuracy, e.g., ±0.1% of span.
Input Burden The voltage drop caused by the input current is typically very low (e.g., <3V).
Voltage Output Load The voltage output can typically drive a minimum load resistance (e.g., 1 kΩ).
Response Time Very fast, typically less than 100 ms.
Operating Temperature -20°C to +70°C (standard industrial range).
Mounting Standard 35mm DIN rail mounting.
Certifications Typically carries international certifications like CE, ATEX, IECEx, FM for use in hazardous areas.
Model Number P0800DV
Product Type Gauge Pressure Transmitter
Pressure Type Gauge Pressure (pressure relative to atmospheric pressure)
Sensor Technology Stable semiconductor technology (e.g., piezoresistive silicon sensor)
Output Signal 4-20 mA analog output, often with HART® Protocol for digital communication.
Accuracy Good industrial accuracy, typically ±0.25% of span (including hysteresis and repeatability). This is a key differentiator from more premium models.
Pressure Ranges (URL) The "DV" suffix typically corresponds to a medium to high pressure range. A common example is 0-400 bar (0-6000 psi). The exact range is defined by the ordering code.
Process Connection Standard: 1/2-14 NPT internal thread.
Wetted Parts Material 316L Stainless Steel is standard for the diaphragm and process connections.
Power Supply 2-wire, 12-45 VDC (loop-powered).
Operating Temperature Ambient: -40°C to +85°C (-40°F to 185°F). Process: Dependent on seal options.
Protection Rating NEMA 4X / IP67 (weatherproof and corrosion-resistant).