Technical Specifications
Parameter Specification / Typical Value
Manufacturer / Brand Eaton
Model Number NZM2/3-XHIV (This is a base model; full code specifies voltage)
Product Line NZM (Accessory for)
Device Type Under-Voltage Release (UVR)
Compatible Breaker Frame NZM2, NZM3
Mounting Mounts directly onto the compatible NZM breaker
Full Ordering Code Example NZM2/3-XHIV400AC (This would specify a 400V AC operating voltage). The voltage must be specified.
Typical Operating Voltages Available for common AC voltages (e.g., 230V, 400V, 500V AC). The specific voltage is CRITICAL.
Trip Threshold Typically trips when voltage drops to 35% - 70% of its rated operating voltage.
Reset Voltage The breaker can typically be reset once the voltage is restored to above approx. 85% of the rated voltage.
Power Consumption Continuously consumes a small amount of power when energized.
Standards Compliance As part of the breaker assembly, it helps comply with IEC 60947-2.
Technical Specifications
Parameter Specification / Typical Value
Manufacturer / Brand Eaton
Model Number NZM2-XRD (This is a base model; full code specifies voltage)
Product Line NZM (Accessory for)
Device Type Shunt Trip Coil / Shunt Release
Compatible Breaker Frame NZM2
Mounting Mounts directly onto the NZM2 breaker
Full Ordering Code Example NZM2-XRD230AC (This would specify a 230V AC operating voltage). The voltage must be specified.
Typical Operating Voltages Available for common AC and DC voltages (e.g., 24V, 48V, 110V, 120V, 230V, 240V AC/DC). The specific voltage is CRITICAL.
Power Consumption Typically a few tens of Watts (VA) for a short duration during operation. Exact value depends on the voltage rating.
Standards Compliance As part of the breaker assembly, it helps comply with IEC 60947-2.
Technical Specifications
Parameter Specification / Typical Value
Manufacturer / Brand Eaton
Model Number NZMN3-A400
Product Line NZM
Rated Current (Iₙ) 400 A
Poles 3
Frame Size NZMN3-A
Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC
Rated Insulation Voltage (Uᵢ) 690 V AC
Rated Frequency 50/60 Hz
Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 50 kA / 65 kA @ 400V (Must be verified from datasheet)
Trip Unit Type Thermal-Magnetic (Non-Adjustable)
Overload Protection (Ir) Fixed at 400A
Short-Circuit Protection (Im) Fixed magnetic trip
Installation Fixed Type
Standards Compliance IEC 60947-2
Electrical Life Several thousand cycles (e.g., 5,000)
Mechanical Life Tens of thousands of cycles (e.g., 20,000)
Terminal Torque Refer to official manual (Specific torque for 400A terminals)
Technical Specifications
Parameter Specification / Typical Value
Manufacturer / Brand Eaton
Model Number NZMH2-A250
Product Line NZM
Rated Current (Iₙ) 250 A
Poles 3
Frame Size NZMH2-A
Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC
Rated Insulation Voltage (Uᵢ) 690 V AC
Rated Frequency 50/60 Hz
Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 36 kA / 50 kA @ 400V (Must be verified from datasheet)
Trip Unit Type Thermal-Magnetic (Non-Adjustable)
Overload Protection (Ir) Fixed at 250A
Short-Circuit Protection (Im) Fixed magnetic trip
Installation Fixed Type
Standards Compliance IEC 60947-2
Electrical Life Several thousand cycles (e.g., 5,000)
Mechanical Life Tens of thousands of cycles (e.g., 20,000)
Terminal Torque Refer to official manual (Specific torque for 250A terminals)
Technical Specifications
Parameter Specification / Typical Value
Manufacturer / Brand Eaton
Model Number NZMH2-A125-BT
Product Line NZM
Rated Current (Iₙ) 125 A
Poles 3
Frame Size NZMH2-A
Mounting Type Fixed
Trip Unit Type Thermal-Magnetic (Non-Adjustable)
Rated Operational Voltage (Uₑ) 400/415 V AC | 690 V AC
Rated Insulation Voltage (Uᵢ) 690 V AC
Rated Frequency 50/60 Hz
Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 36 kA / 50 kA @ 400V (Must be verified from datasheet)
Integrated Accessory Trip Alarm Contact (1 NO)
Accessory Contact Rating Typically AC-15: 230V / 5A (Please verify from manual)
Standards Compliance IEC 60947-2
Technical Specifications
Parameter Specification / Typical Value
Manufacturer / Brand Eaton
Model Number NZMN2-M160
Product Line NZM
Rated Current (Iₙ) 160 A
Poles 3
Frame Size NZMN2-M
Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC
Rated Insulation Voltage (Uᵢ) 690 V AC
Rated Frequency 50/60 Hz
Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 50 kA @ 400V (Must be verified from datasheet)
Trip Unit Type Thermal-Magnetic (Non-Adjustable)
Overload Protection (Ir) Fixed at 160A
Short-Circuit Protection (Im) Fixed magnetic trip
Installation Fixed Type
Standards Compliance IEC 60947-2
Electrical Life Several thousand cycles (e.g., 5,000)
Mechanical Life Tens of thousands of cycles (e.g., 20,000)
Terminal Torque Refer to official manual (Specific torque for 160A terminals)
Technical Specifications
Parameter Specification / Typical Value
Manufacturer / Brand Eaton
Model Number NZMS2-A200
Product Line NZM
Rated Current (Iₙ) 200 A
Poles 3
Frame Size NZMS2-A
Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC
Rated Insulation Voltage (Uᵢ) 690 V AC
Rated Frequency 50/60 Hz
Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 36 kA / 50 kA @ 400V (Must be verified from datasheet)
Trip Unit Type Thermal-Magnetic (Non-Adjustable)
Overload Protection (Ir) Fixed at 200A
Short-Circuit Protection (Im) Fixed magnetic trip
Installation Fixed Type
Standards Compliance IEC 60947-2
Electrical Life Several thousand cycles (e.g., 5,000)
Mechanical Life Tens of thousands of cycles (e.g., 20,000)
Terminal Torque Refer to official manual (Specific torque for 200A terminals)
典型应用 (Typical Applications):
Technical Specifications
Parameter Specification / Typical Value
Manufacturer / Brand Eaton
Model Number NZMN1-A125
Product Line NZM
Rated Current (Iₙ) 125 A
Poles 3
Frame Size NZMN1-A
Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC
Rated Insulation Voltage (Uᵢ) 690 V AC
Rated Frequency 50/60 Hz
Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 36 kA / 50 kA @ 400V (Must be verified from datasheet)
Trip Unit Type Thermal-Magnetic (Non-Adjustable)
Overload Protection (Ir) Fixed at 125A
Short-Circuit Protection (Im) Fixed magnetic trip
Installation Fixed Type
Standards Compliance IEC 60947-2
Electrical Life Several thousand cycles (e.g., 5,000)
Mechanical Life Tens of thousands of cycles (e.g., 20,000)
Terminal Torque Refer to official manual (Specific torque for 125A terminals)
Technical Specifications
Parameter Specification / Typical Value
Manufacturer / Brand Eaton
Model Number NZMC1-A100
Product Line NZM
Rated Current (Iₙ) 100 A
Poles 3
Frame Size NZMC1-A
Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC
Rated Insulation Voltage (Uᵢ) 690 V AC
Rated Frequency 50/60 Hz
Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 36 kA / 50 kA @ 400V (Must be verified from datasheet)
Trip Unit Type Thermal-Magnetic (Non-Adjustable)
Overload Protection (Ir) Fixed at 100A
Short-Circuit Protection (Im) Fixed magnetic trip
Installation Fixed Type
Standards Compliance IEC 60947-2
Electrical Life Several thousand cycles
Mechanical Life Tens of thousands of cycles
Terminal Torque Refer to official manual (Specific torque for 100A terminals)
Technical Specifications
Parameter Specification / Typical Value
Manufacturer / Brand Eaton
Model Number LZMN1-A160
Product Line NZM
Rated Current (Iₙ) 160 A
Poles 3
Frame Size NZM1-A
Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC
Rated Insulation Voltage (Uᵢ) 690 V AC
Rated Frequency 50/60 Hz
Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 25 kA / 36 kA @ 400V (Must be verified from datasheet)
Trip Unit Type Thermal-Magnetic (Non-Adjustable)
Overload Protection (Ir) Fixed at 160A
Short-Circuit Protection (Im) Fixed magnetic trip
Installation Fixed Type
Standards Compliance IEC 60947-2
Electrical Life Several thousand cycles (e.g., 5,000)
Mechanical Life Tens of thousands of cycles (e.g., 20,000)
Terminal Torque Refer to official manual (Specific torque for 160A terminals)