Products
Products
home
eaton
EASY618-AC-RE
Technical Parameters Parameter Category Specification Details General Model EASY618-AC-RE EASY Series, 600V, Self-Powered, Specific Function Set Product Line Eaton EASY Motor Relay Power Supply Auxiliary Power Not Required (Self-Powered). Operates directly from the monitored motor current and line voltage. Electrical Characteristics Rated Operational Voltage (Ue) Up to 690V AC Rated Insulation Voltage (Ui) 750V AC Current Setting Range (I~r~) Typically 0.1A to 63A (adjustable via DIP switches and a potentiometer). Specific ranges depend on the internal CT. Power Consumption None (Self-Powered) Protection Functions Overload (ANSI 49) Yes, with selectable tripping class (10, 15, 20, 30) Phase Loss / Unbalance (ANSI 46) Yes Locked Rotor / Jam (ANSI 48/51) Yes Short-Circuit (ANSI 50) Yes Earth Fault (ANSI 51G/50G) Yes (Residual current type) Undercurrent (ANSI 37) Yes Control & Output Output Relays At least one volt-free changeover (CO) contact for Trip/Alarm. Reset Function Automatic or Manual (selectable) Mechanical Characteristics Mounting Standard 35mm DIN Rail Connection Screw terminals Standards & Compliance Safety Standards UL 508, CSA C22.2 No. 14, CE, IEC/EN 60947-4-1, IEC/EN 60947-5-1

More details >> Request a Quote >>
eaton
EU5E-SWD-8DX
Technical Parameters Parameter Category Specification Details General Model EU5E-SWD-8DX Form 4S, Three-Phase, 4-Wire Advanced Power Meter Product Line Eaton Crouse-Hinds Series / Power Xpert Metering Electrical Characteristics System Type Three-Phase, 4-Wire (3P4W - Wye) Rated Voltage 347/600V AC (Line-to-Line) Current Input Via external Current Transformers (CTs) with standard secondary ratings of 5A or 1A. Frequency 50/60 Hz Measurement Capabilities Basic Parameters Volts (L-N, L-L), Amps, Frequency, Real/Reactive/Apparent Power (kW, kvar, kVA), Power Factor, Demand (current & power) Energy Import/Export kWh, kvarh Power Quality Voltage and Current THD, Individual Harmonics (up to 63rd), K-Factor, Unbalance, Min/Max/Average values, Sag/Swell/Interruption log. Advanced Features Waveform Capture, Event Logging, Phasor Diagrams. Communication Standard Ports Typically includes Ethernet (for Modbus TCP/IP or BACnet IP) and other serial ports like RS-485. Protocols Modbus TCP/IP, BACnet IP, Modbus RTU over RS-485 are common. Display High-resolution, backlit graphical LCD with intuitive navigation. Accuracy Standard ANSI C12.20 Class 0.2 (Revenue Grade) Voltage & Current ±0.1% of Reading (typical) Power & Energy ±0.2% of Reading (typical) Physical & Environmental Mounting Hardwired installation into a dedicated meter socket within an Eaton panelboard or enclosure. Operating Temperature -40°C to +70°C (-40°F to +158°F)

More details >> Request a Quote >>
eaton
EU5E-SWD-4D4D
Technical Parameters Parameter Category Specification Details General Model EU5E-SWD-4D4D Form 4S, Three-Phase, 4-Wire Meter with advanced digital features. Product Line Eaton Crouse-Hinds Series / Power Xpert Metering Electrical Characteristics System Type Three-Phase, 4-Wire (3P4W - Wye) Rated Voltage 347/600V AC (Line-to-Line) Operating Voltage Range Typically up to 600V AC L-L Current Input Via external Current Transformers (CTs). Common secondary ratings: 5A or 1A. Frequency 50/60 Hz Measurement Capabilities Basic Parameters Volts (L-N, L-L), Amps, Frequency, Real/Reactive/Apparent Power (kW, kvar, kVA), Power Factor, Demand (kW, kVA, A) Energy Import/Export kWh, kvarh Power Quality Total Harmonic Distortion (THD) for V & I, Individual Harmonics up to the 63rd, Min/Max/Average recordings, Sag/Swell detection. Communication Communication Slots 2 slots for optional communication modules. Available Protocols Modbus TCP/IP, BACnet IP, SNMP, and others via plug-in cards. Display & Interface Integrated large, backlit LCD with navigation buttons. Accuracy Standard ANSI C12.20 Class 0.2 (Extremely high accuracy, revenue grade) Voltage & Current ±0.2% of Reading Power & Energy ±0.2% of Reading Physical & Environmental Mounting Hardwired installation into a dedicated meter socket within an Eaton enclosure. Operating Temperature -40°C to +70°C (-40°F to +158°F)

More details >> Request a Quote >>
eaton
SN4-050-B17
Technical Parameters Parameter Category Specification Details General Model SN4-050-B17 S Series, 4-pole, specific coil voltage and contact configuration. Product Line Eaton S Series Contact Characteristics Number of Poles 4 Contact Type Changeover (Form C, SPDT) - Each pole has Common (C), Normally Open (NO), and Normally Closed (NC) terminals. Rated Operational Current (Ith) Typically 5 A (e.g., at 240V AC) Rated Thermal Current (Ithe) 10 A Rated Impulse Withstand Voltage (Uimp) 6 kV Rated Operational Voltage (Ue) Up to 250V AC / 30V DC Coil Characteristics Coil Voltage Code 050 (This code corresponds to a specific voltage. The most common interpretation for 050 is 240V AC. However, this must be verified.) Coil Power Consumption Approx. 4.5 VA (AC) / 1.8 W (DC) - typical values Mechanical Characteristics Electrical Durability > 10 million operations (at rated operational current) Mechanical Durability > 20 million operations Mounting Snap-on side mounting to compatible S Series contactors (e.g., DILM contactors) or onto a standard 35mm DIN rail using an optional adapter. Standards & Compliance Safety Standards UL 508, CSA C22.2 No. 14, CE, cULus, IEC/EN 60947-5-1

More details >> Request a Quote >>
eaton
XN-2DO-R-CO
Technical Parameters Parameter Category Specification Details / Notes General Model XN-2DO-R-CO 2 Digital Outputs, Relay, Change-Over Product Line Eaton X-Nergy Part of the Moeller series of control products. Output Characteristics Number of Channels 2 Contact Type Change-Over (Form C, SPDT) • Common (C) • Normally Open (NO) • Normally Closed (NC) Rated Current 5 A @ 250V AC 5 A @ 30V DC Max. Switching Voltage 250V AC / 30V DC Max. Switching Power 1250 VA / 750 W (AC) 90 W (DC) Electrical Durability Typically > 100,000 cycles (at rated load) Mechanical Durability Typically > 10,000,000 cycles Control & Communication Control Supply Voltage Provided via the X-Nergy base (e.g., 24V DC from XN-BR-24VDC-D). The logic side is powered by this bus voltage. Communication Bus X-Nergy System Bus (integrated into the base). Status Indication LED Indicators 2 yellow/green LEDs (one per channel) to indicate the output state. Electrical Connection Field-Side Connection Screw clamp terminals for load wiring (C, NO, NC for each channel). Control-Side Connection Via plug-in connection to the X-Nergy base. Mechanical Characteristics Mounting Plugs onto a standard 35mm DIN rail via the X-Nergy base. Module Width Multiple of a standard module width (e.g., 45mm). Standards & Approvals Safety & EMC UL 508, CSA C22.2 No. 14, CE marked, cULus listed.

More details >> Request a Quote >>
eaton
XN-BR-24VDC-D
Technical Parameters Parameter Category Specification Details General Model XN-BR-24VDC-D X-Nergy Base, 24V DC Power Supply Product Line Eaton X-Nergy Input Characteristics Input Voltage 100-240V AC, 50/60 Hz (Wide-range input) Output Characteristics Output Voltage 24V DC Rated Output Current Typically 1.3 A (Verify from datasheet for exact capacity to ensure it can power all connected modules). Power Rating Typically ~30W. System Characteristics Module Capacity Can physically accommodate and power a specific number of X-Nergy modules (e.g., 4 or 8 modules). The total current draw of all modules must not exceed the base's output current. Communication Bus Integrated X-Nergy communication and power bus. Mechanical Characteristics Mounting Standard 35mm DIN Rail Connection Screw terminals for AC input and optional external wiring. Standards & Compliance Safety Standards UL 508, CSA C22.2 No. 14, CE, cULus

More details >> Request a Quote >>
eaton
CAN-16DO/R-NO
Technical Parameters Category Specification Product Model CAN-16DO/R-NO Product Type Digital Output Module Communication Protocol CANopen (CiA DS-301, CIA DSP-401) Number of Channels 16 Output Type Electromechanical Relay, Normally Open (SPST - Form A) Contact Rating - 2 A @ 250 V AC - 2 A @ 30 V DC Electrical Life > 100,000 cycles (at rated load) Mechanical Life > 10,000,000 cycles Isolation - Channel-to-Channel: Yes - Channel-to-Bus: Yes (Optically isolated) Connection Method Removable screw terminal block Supply Voltage 24 V DC Power Consumption Typically < 5 W (dependent on active relays) Status Indicators - PWR (Power): Green LED - CAN (Network): Green/Red LED - OUTx (Output): Green LED per channel IP Rating IP20 (for enclosure mounting) Mounting Standard 35 mm DIN rail Operating Temperature 0 °C to +55 °C (32 °F to 131 °F) Storage Temperature -25 °C to +85 °C (-13 °F to 185 °F) Relative Humidity 95% (non-condensing)

More details >> Request a Quote >>
eaton
XN-16DI-24VDC-P
Technical Parameters Category Specification Product Model XN-16DI-24VDC-P Product Type Digital Input Module Number of Channels 16 Input Type 24 V DC, Sourcing (PNP compatible) Nominal Voltage 24 V DC Rated Input Voltage "1" 15 V DC to 30 V DC Rated Input Voltage "0" -30 V DC to 5 V DC Input Current Typically 3 mA per input (at 24 V DC) Connection Type 2-wire Isolation Channel-to-Bus: Yes (Optically isolated) Connection Method Removable screw terminal block Module Power Supply 24 V DC (via the XN system base or terminal block) Status Indicators - PWR (Power): Green LED - SF (System Fault): Red LED - INx (Input Status): Green LED per channel IP Rating IP20 (for enclosure mounting) Mounting On an XN system base unit, which is mounted on a standard 35 mm DIN rail Operating Temperature -25 °C to +55 °C (-13 °F to 131 °F) Storage Temperature -40 °C to +85 °C (-40 °F to 185 °F) Relative Humidity 95% (non-condensing)

More details >> Request a Quote >>
eaton
DS6-340-30K37K-MX
Technical Parameters Category Specification Product Model DS6-340-30K37K-MX Product Type Programmable Electronic Pressure Switch Pressure Ranges Channel 1 (K1): 30 bar (435 psi) Channel 2 (K2): 37 bar (537 psi) Note: Multiple range combinations are available in the DS6 series. Pressure Media Hydraulic oil, lubricating oil, air, water (compatible with wetted materials) Wetted Materials Stainless Steel Electrical Connection Output 1: 2x PNP/NPN, 0.5A (Relay function) Output 2: 1x PNP/NPN, 0.5A (Relay function) Analog Output: 1x 4...20 mA or 0...10 V (programmable) Supply Voltage 12...30 V DC (Universal) Accuracy Typically ≤ ±1.0% Full Scale (FS) Display Multi-digit LCD with bargraph and status indicators Programming Interface - Integrated buttons and display - Easy Menu PC Software (via communication interface) Electrical Connector M12 x 1 circular connector Pressure Port G ¼" (external) or other options depending on variant Protection Rating IP66 / IP67 (Dust-tight and protected against water immersion) Operating Temperature -40 °C to +85 °C (-40 °F to +185 °F) Media Temperature -40 °C to +100 °C (-40 °F to +212 °F)

More details >> Request a Quote >>
eaton
XV-102-D6
Technical Parameters Category Specification Product Model XV-102-D6 Product Line Viking® Valve Type 5/2-way (5 ports, 2 positions) Actuation Type Solenoid (The "D" in D6 typically indicates single or double solenoid). Note: The exact configuration (single solenoid with spring return or double solenoid) should be confirmed from the datasheet. Port Size 1/4" (NPT standard) Operating Pressure Range 30 to 150 psi (2 to 10 bar) Media Compressed Air, as per ISO 8573-1:2010 [7:4:4] Voltage Options Various AC and DC voltages are available (e.g., 24 V DC, 110 V AC, 230 V AC). The specific voltage must be confirmed from the valve's label or ordering code. Standard CE, RoHS compliant Body Material Die-cast Zinc Seal Material NBR (Nitrile Rubber) Temperature Range Media & Ambient: 14° to 140°F (-10° to 60°C) Flow Coefficient (Cv) Approximately 1.8 (This is a typical value for this port size; confirms flow capacity) Mounting Base-mounted (Sub-base) Electrical Connection Standard DIN 43650 Form A (for solenoids)

More details >> Request a Quote >>
1 2
··· ···