Products
Products
home
eaton
LZMC1-A63
Technical Parameters Parameter Specification Product Series Eaton LZMC1 Product Type Molded Case Circuit Breaker (MCCB) Rated Operational Current (Ie) 63 A Poles 3 Trip Unit Type Fixed Thermal-Magnetic Rated Operational Voltage (Ue) Up to 690 V AC Rated Insulation Voltage (Ui) 800 V AC Rated Frequency 50/60 Hz Short-Circuit Breaking Capacity (Icu) Typically 10 kA to 25 kA (e.g., at 400V AC per IEC 60947-2). Must be verified from the specific catalog/datasheet. Mounting Fixed Mounting (on DIN Rail or panel) Standards Compliance IEC 60947-2, UL 489, CSA C22.2 No. 5

More details >> Request a Quote >>
eaton
BZMB2-A250
Technical Parameters Parameter Specification Product Series Eaton BZMB2 Product Type Molded Case Circuit Breaker (MCCB) Rated Operational Current (Ie) 250 A Poles 3 Trip Unit Type Fixed Thermal-Magnetic Rated Operational Voltage (Ue) Up to 690 V AC Rated Insulation Voltage (Ui) 1000 V AC Rated Frequency 50/60 Hz Short-Circuit Breaking Capacity (Icu) Typically 25 kA to 36 kA at 415V AC (IEC 60947-2). Must be verified from the specific catalog/datasheet. Mounting Fixed Mounting Standards Compliance IEC 60947-2, UL 489, CSA C22.2 No. 5

More details >> Request a Quote >>
eaton
IQ100PEMA5511
Technical Parameters Parameter Specification Product Series Eaton IQ100 Product Type RCBO (Residual Current Breaker with Overcurrent) Number of Poles 1 Pole + Neutral (1P+N) Rated Current (In) 16 A Rated Voltage 230 V AC Rated Residual Current (IΔn) 30 mA RCD Type Type A (Sensitive to AC and pulsating DC residual currents) Tripping Characteristic (MCB) Type C (Instantaneous trip: 5 to 10 x In) Rated Breaking Capacity (Icn) 10 kA (10,000 A) Standards Compliance IEC 61009-1, IEC 60898-1 Mechanical Life ≥ 20,000 cycles Mounting DIN Rail Mounting (35 mm) Width (Modular Size) 18 mm (1 module)

More details >> Request a Quote >>
eaton
IQ200XMA5512
Technical Parameters Parameter Specification Product Series Eaton IQ200 Product Type RCBO (Residual Current Breaker with Overcurrent) Number of Poles 1 Pole + Neutral (1P+N) Rated Current (In) 25 A Rated Voltage 230 V AC Rated Residual Current (IΔn) 30 mA RCD Type Type A (Sensitive to AC and pulsating DC residual currents) Tripping Characteristic (MCB) Type C (Instantaneous trip: 5 to 10 x In) Rated Breaking Capacity (Icn) 6 kA (6,000 A) Standards Compliance IEC 61009-1, IEC 60898-1 Mechanical Life ≥ 20,000 cycles Mounting DIN Rail Mounting (35 mm) Width (Modular Size) 18 mm (1 module)

More details >> Request a Quote >>
eaton
IQ100XEMA5512
Technical Parameters Parameter Specification Product Series Eaton IQ100 Product Type RCBO (Residual Current Breaker with Overcurrent) Number of Poles 1 Pole + Neutral (1P+N) Rated Current (In) 25 A Rated Voltage 230 V AC Rated Residual Current (IΔn) 30 mA RCD Type Type A (Sensitive to AC and pulsating DC residual currents) Tripping Characteristic (MCB) Type C (Instantaneous trip: 5 to 10 x In) Rated Breaking Capacity (Icn) 10 kA (10,000 A) Standards Compliance IEC 61009-1, IEC 60898-1 Mechanical Life ≥ 20,000 cycles Mounting DIN Rail Mounting (35 mm) Width (Modular Size) 18 mm (1 module)

More details >> Request a Quote >>
eaton
IQ200XMA5511
Technical Parameters Parameter Specification Product Series Eaton IQ200 Product Type RCBO (Residual Current Breaker with Overcurrent) Number of Poles 1 Pole + Neutral (1P+N) Rated Current (In) 16 A Rated Voltage 230 V AC Rated Residual Current (IΔn) 30 mA RCD Type Type A (Sensitive to AC and pulsating DC residual currents) Tripping Characteristic (MCB) Type C (Instantaneous trip: 5 to 10 x In) Rated Breaking Capacity (Icn) 10 kA (10,000 A) Standards Compliance IEC 61009-1, IEC 60898-1 Mechanical Life ≥ 20,000 cycles Mounting DIN Rail Mounting (35 mm) Width (Modular Size) 18 mm (1 module)

More details >> Request a Quote >>
eaton
IQ100XEMA5511
Technical Parameters Parameter Specification Product Series Eaton IQ100 Product Type RCBO (Residual Current Breaker with Overcurrent) Number of Poles 1 Pole + Neutral (1P+N) Rated Current (In) 16 A Rated Voltage 230 V AC Rated Residual Current (IΔn) 30 mA RCD Type Type A (Sensitive to AC and pulsating DC residual currents) Tripping Characteristic (MCB) Type C (Instantaneous trip: 5 to 10 x In) Rated Breaking Capacity (Icn) 10 kA (10,000 A) Standards Compliance IEC 61009-1, IEC 60898-1 Mechanical Life ≥ 20,000 cycles Mounting DIN Rail Mounting (35 mm) Width (Modular Size) 18 mm (1 module)

More details >> Request a Quote >>
eaton
ZP-IHK
Technical Parameters Parameter Typical Specification / Description Product Series Eaton ZP (Accessories for Power Distribution) Product Type Insulated Hub Kit / Cable Gland Kit Material Polyamide (PA) or other robust, insulating plastic Sealing Ring Material EPDM or NBR IP Rating (when properly installed) IP66 / IP67 Temperature Range e.g., -40°C to +100°C Nominal Entry Size Specific metric or PG thread size (e.g., M25, M32, PG21) [Must be confirmed from the specific kit] Suitable Cable Diameter Range Specified for each hub size (e.g., for cables from 8mm to 13mm) Standards Compliance IEC 60947-7-2, UL, CSA

More details >> Request a Quote >>
eaton
NZM4-XKV110
Technical Parameters Parameter Specification Product Series Eaton NZM4 Product Type Electronic Trip Unit with Communication Rated Current (In) of Frame 1100 A (This is the fixed rating for this specific trip unit) Rated Operational Voltage (Ue) Up to 690 V AC Rated Insulation Voltage (Ui) 1000 V AC Rated Frequency 50/60 Hz Protection Functions L (Long-time), S (Short-time), I (Instantaneous), G (Ground Fault) Communication Protocol Modbus RTU (via RS-485 interface) - Verify specific protocol from datasheet Setting Adjustment Programmable via front interface or communication network Display Typically includes an LCD for status and fault indication Mounting Integrated into a compatible NZM4 circuit breaker frame Standards Compliance IEC 60947-2

More details >> Request a Quote >>
eaton
NZM4-XTVD-NA
Technical Parameters Parameter Specification Product Series Eaton NZM4 Product Type Programmable Electronic Trip Unit with Metering & Communication Rated Current (In) of Frame The specific current rating is not defined by "XTVD-NA" alone. It must be matched with a compatible NZM4 breaker frame (e.g., 800A, 1600A, 3200A). Rated Operational Voltage (Ue) Up to 690 V AC Rated Insulation Voltage (Ui) 1000 V AC Rated Frequency 50/60 Hz Protection Functions L (Long-time), S (Short-time), I (Instantaneous), G (Ground Fault) Measurement Parameters Current, Voltage, Power, Power Factor, Frequency, Energy, etc. Communication Protocol Modbus RTU (via RS-485 interface) - Verify specific protocol from datasheet Display Integrated LCD Setting Adjustment Programmable via front interface or communication network Mounting Integrated into a compatible NZM4 circuit breaker frame Standards Compliance IEC 60947-2

More details >> Request a Quote >>