eaton
NZM2/3-XHIV
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number NZM2/3-XHIV (This is a base model; full code specifies voltage) Product Line NZM (Accessory for) Device Type Under-Voltage Release (UVR) Compatible Breaker Frame NZM2, NZM3 Mounting Mounts directly onto the compatible NZM breaker Full Ordering Code Example NZM2/3-XHIV400AC (This would specify a 400V AC operating voltage). The voltage must be specified. Typical Operating Voltages Available for common AC voltages (e.g., 230V, 400V, 500V AC). The specific voltage is CRITICAL. Trip Threshold Typically trips when voltage drops to 35% - 70% of its rated operating voltage. Reset Voltage The breaker can typically be reset once the voltage is restored to above approx. 85% of the rated voltage. Power Consumption Continuously consumes a small amount of power when energized. Standards Compliance As part of the breaker assembly, it helps comply with IEC 60947-2.

More details >> Request a Quote >>
eaton
NZM2-XRD
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number NZM2-XRD (This is a base model; full code specifies voltage) Product Line NZM (Accessory for) Device Type Shunt Trip Coil / Shunt Release Compatible Breaker Frame NZM2 Mounting Mounts directly onto the NZM2 breaker Full Ordering Code Example NZM2-XRD230AC (This would specify a 230V AC operating voltage). The voltage must be specified. Typical Operating Voltages Available for common AC and DC voltages (e.g., 24V, 48V, 110V, 120V, 230V, 240V AC/DC). The specific voltage is CRITICAL. Power Consumption Typically a few tens of Watts (VA) for a short duration during operation. Exact value depends on the voltage rating. Standards Compliance As part of the breaker assembly, it helps comply with IEC 60947-2.

More details >> Request a Quote >>
eaton
NZMN3-A400
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number NZMN3-A400 Product Line NZM Rated Current (Iₙ) 400 A Poles 3 Frame Size NZMN3-A Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC Rated Insulation Voltage (Uᵢ) 690 V AC Rated Frequency 50/60 Hz Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 50 kA / 65 kA @ 400V (Must be verified from datasheet) Trip Unit Type Thermal-Magnetic (Non-Adjustable) Overload Protection (Ir) Fixed at 400A Short-Circuit Protection (Im) Fixed magnetic trip Installation Fixed Type Standards Compliance IEC 60947-2 Electrical Life Several thousand cycles (e.g., 5,000) Mechanical Life Tens of thousands of cycles (e.g., 20,000) Terminal Torque Refer to official manual (Specific torque for 400A terminals)

More details >> Request a Quote >>
eaton
NZMH2-A250
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number NZMH2-A250 Product Line NZM Rated Current (Iₙ) 250 A Poles 3 Frame Size NZMH2-A Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC Rated Insulation Voltage (Uᵢ) 690 V AC Rated Frequency 50/60 Hz Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 36 kA / 50 kA @ 400V (Must be verified from datasheet) Trip Unit Type Thermal-Magnetic (Non-Adjustable) Overload Protection (Ir) Fixed at 250A Short-Circuit Protection (Im) Fixed magnetic trip Installation Fixed Type Standards Compliance IEC 60947-2 Electrical Life Several thousand cycles (e.g., 5,000) Mechanical Life Tens of thousands of cycles (e.g., 20,000) Terminal Torque Refer to official manual (Specific torque for 250A terminals)

More details >> Request a Quote >>
eaton
NZMH2-A125-BT
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number NZMH2-A125-BT Product Line NZM Rated Current (Iₙ) 125 A Poles 3 Frame Size NZMH2-A Mounting Type Fixed Trip Unit Type Thermal-Magnetic (Non-Adjustable) Rated Operational Voltage (Uₑ) 400/415 V AC | 690 V AC Rated Insulation Voltage (Uᵢ) 690 V AC Rated Frequency 50/60 Hz Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 36 kA / 50 kA @ 400V (Must be verified from datasheet) Integrated Accessory Trip Alarm Contact (1 NO) Accessory Contact Rating Typically AC-15: 230V / 5A (Please verify from manual) Standards Compliance IEC 60947-2

More details >> Request a Quote >>
eaton
NZMN2-M160
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number NZMN2-M160 Product Line NZM Rated Current (Iₙ) 160 A Poles 3 Frame Size NZMN2-M Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC Rated Insulation Voltage (Uᵢ) 690 V AC Rated Frequency 50/60 Hz Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 50 kA @ 400V (Must be verified from datasheet) Trip Unit Type Thermal-Magnetic (Non-Adjustable) Overload Protection (Ir) Fixed at 160A Short-Circuit Protection (Im) Fixed magnetic trip Installation Fixed Type Standards Compliance IEC 60947-2 Electrical Life Several thousand cycles (e.g., 5,000) Mechanical Life Tens of thousands of cycles (e.g., 20,000) Terminal Torque Refer to official manual (Specific torque for 160A terminals)

More details >> Request a Quote >>
eaton
NZMS2-A200
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number NZMS2-A200 Product Line NZM Rated Current (Iₙ) 200 A Poles 3 Frame Size NZMS2-A Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC Rated Insulation Voltage (Uᵢ) 690 V AC Rated Frequency 50/60 Hz Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 36 kA / 50 kA @ 400V (Must be verified from datasheet) Trip Unit Type Thermal-Magnetic (Non-Adjustable) Overload Protection (Ir) Fixed at 200A Short-Circuit Protection (Im) Fixed magnetic trip Installation Fixed Type Standards Compliance IEC 60947-2 Electrical Life Several thousand cycles (e.g., 5,000) Mechanical Life Tens of thousands of cycles (e.g., 20,000) Terminal Torque Refer to official manual (Specific torque for 200A terminals) 典型应用 (Typical Applications):

More details >> Request a Quote >>
eaton
NZMN1-A125
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number NZMN1-A125 Product Line NZM Rated Current (Iₙ) 125 A Poles 3 Frame Size NZMN1-A Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC Rated Insulation Voltage (Uᵢ) 690 V AC Rated Frequency 50/60 Hz Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 36 kA / 50 kA @ 400V (Must be verified from datasheet) Trip Unit Type Thermal-Magnetic (Non-Adjustable) Overload Protection (Ir) Fixed at 125A Short-Circuit Protection (Im) Fixed magnetic trip Installation Fixed Type Standards Compliance IEC 60947-2 Electrical Life Several thousand cycles (e.g., 5,000) Mechanical Life Tens of thousands of cycles (e.g., 20,000) Terminal Torque Refer to official manual (Specific torque for 125A terminals)

More details >> Request a Quote >>
eaton
NZMC1-A100
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number NZMC1-A100 Product Line NZM Rated Current (Iₙ) 100 A Poles 3 Frame Size NZMC1-A Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC Rated Insulation Voltage (Uᵢ) 690 V AC Rated Frequency 50/60 Hz Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 36 kA / 50 kA @ 400V (Must be verified from datasheet) Trip Unit Type Thermal-Magnetic (Non-Adjustable) Overload Protection (Ir) Fixed at 100A Short-Circuit Protection (Im) Fixed magnetic trip Installation Fixed Type Standards Compliance IEC 60947-2 Electrical Life Several thousand cycles Mechanical Life Tens of thousands of cycles Terminal Torque Refer to official manual (Specific torque for 100A terminals)

More details >> Request a Quote >>
eaton
LZMN1-A160
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number LZMN1-A160 Product Line NZM Rated Current (Iₙ) 160 A Poles 3 Frame Size NZM1-A Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC Rated Insulation Voltage (Uᵢ) 690 V AC Rated Frequency 50/60 Hz Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 25 kA / 36 kA @ 400V (Must be verified from datasheet) Trip Unit Type Thermal-Magnetic (Non-Adjustable) Overload Protection (Ir) Fixed at 160A Short-Circuit Protection (Im) Fixed magnetic trip Installation Fixed Type Standards Compliance IEC 60947-2 Electrical Life Several thousand cycles (e.g., 5,000) Mechanical Life Tens of thousands of cycles (e.g., 20,000) Terminal Torque Refer to official manual (Specific torque for 160A terminals)