Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, PLHT Series
Model Number PLHT-B100
Fuse Standard & Rating IEC gG (General Application)
Rated Current: 100 A
Fuse System NH (Neozed) Style Size B
Rated Voltage 500V AC (690V AC also available - check specific catalog)
Breaking Capacity 50 kA / 100 kA (Depending on specific type and certification)
Standards Compliance IEC 60269-1, IEC 60269-2-1
Contact Type Knife-blade contacts for secure connection in fuse bases
Indicator Visual blown indicator (standard in PLHT series)
Mounting Requires compatible NH fuse base size B
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, FAZ Series (Bussmann)
Model Number FAZ-C16/4
Fuse Class & Rating Class CC
Rated Current: 16 A
Rated Voltage: 600V AC
Number of Poles / Quantity 4 pieces (4-pole set for 3-phase + Neutral applications)
Type Fast-Acting (Non-Time-Delay)
Rated Voltage 600V AC / 300V DC
Rated Breaking Capacity 200 kA AC (200,000 Amps) at 600V AC
Approvals / Standards UL 248-4 (Class CC), CSA C22.2 No. 248.4
Electrical Characteristics Current-Limiting: Yes
Physical Dimensions Body: 13/32" x 1-1/2" (10.3mm diameter x 38.1mm length)
Mounting Requires compatible Class CC fuse holder or fuse block
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, NZM Series
Model Number NZM3-XR
Number of Poles 3-Pole
Mounting Type Draw-Out Version (Fixed mounting in draw-out frame)
Rated Ultimate Breaking Capacity (Icu) Up to 100 kA (Depending on specific current rating and voltage)
Rated Service Breaking Capacity (Ics) Typically 100% of Icu
Rated Operational Voltage (Ue) Up to 690V AC
Rated Insulation Voltage (Ui) 1000V AC
Rated Impulse Withstand Voltage (Uimp) 12 kV
Frame Size Varies (e.g., NZM3-XR available in multiple frame sizes: 400A, 630A, etc.)
Trip Unit Options Available with Thermal-Magnetic (TMD) or Electronic (AE/ME) trip units
Standard Compliance IEC/EN 60947-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, LZMC Series
Model Number LZMC3-A400
Number of Poles 3-Pole
Rated Current 400 A (Frame Size)
Rated Operational Voltage (Ue) Up to 690V AC
Breaking Capacity High interrupting capacity (Specific kA rating depends on voltage - typically 35-65kA range)
Trip Unit Type Type A - Adjustable Electronic Trip Unit
Protection Functions L - Long-time Delay (Overload)
S - Short-time Delay (Short-Circuit)
I - Instantaneous (Short-Circuit)
Standards Compliance IEC 60947-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, PN Series
Model Number PN3-400
Number of Poles 3-Pole
Rated Current 400 A
Rated Operational Voltage (Ue) Up to 690V AC
Breaking Capacity (Icu) 50 kA at 415V AC (Typical - confirm with specific catalog)
Trip Unit Type Thermal-Magnetic (Fixed characteristics)
Standards Compliance IEC 60947-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, NZM Series
Model Number NZMH4-AE1250
Number of Poles 4-Pole
Rated Current 1250 A (Frame Size)
Rated Operational Voltage (Ue) Up to 690V AC
Rated Ultimate Breaking Capacity (Icu) Typically 65 kA / 85 kA at 415V AC (Confirm with specific datasheet)
Trip Unit Type AE - Advanced Electronic Trip Unit with LCD Display
Protection Functions L - Long-time Delay (Overload)
S - Short-time Delay (Short-Circuit)
I - Instantaneous (Short-Circuit)
G - Ground-Fault (Earth Leakage)
Standards Compliance IEC 60947-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, E-Frame Series
Model Number E125E
Rated Current 125 A (Frame Size)
Pole Configurations Available in 1, 2, and 3-pole versions (specific model varies)
Rated Voltage 120/240V AC for 1-2 poles
240V AC for 3 poles
Interrupting Rating 10 kA / 14 kA / 22 kA (Depending on specific version and certification)
Trip Characteristics Thermal-Magnetic
• Thermal Trip: Inverse time delay for overloads
• Magnetic Trip: Instantaneous for short-circuits
Standards Compliance UL 489, CSA C22.2 No. 5
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, NZM Series
Model Number NZMN2-A125
Number of Poles 2-Pole
Rated Current 125 A (Frame Size)
Rated Operational Voltage (Ue) Up to 480V AC
Rated Insulation Voltage (Ui) 690V AC
Rated Ultimate Breaking Capacity (Icu) Typically 25 kA / 35 kA at 480V AC (Confirm with specific datasheet)
Trip Unit Type Type A - Adjustable Electronic Trip Unit
Protection Functions L - Long-time Delay (Overload)
S - Short-time Delay (Short-Circuit)
I - Instantaneous (Short-Circuit)
Standards Compliance IEC 60947-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, NZM Series
Model Designation NZM2
Frame Size Compact Frame (Specific current ratings typically up to 160A)
Pole Configurations Available in 2, 3, and 4-pole versions
Rated Operational Voltage (Ue) Up to 690V AC
Rated Insulation Voltage (Ui) 750V AC / 800V AC
Breaking Capacity High interrupting rating (Typically 25kA to 50kA depending on specific model and voltage)
Trip Unit Options Available with Thermal-Magnetic (TMD) or Electronic (A/ME) trip units
Standards Compliance IEC 60947-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, ETR4 Series
Model Number ETR4-11-A
Poles 3-Pole
Trip Class Class 10
Current Setting Range 0.11 - 0.16 A
Rated Operational Voltage (Ue) 690V AC
Rated Insulation Voltage (Ui) 1000V AC
Ambient Temperature Range -25°C to +60°C (Derating may apply above +50°C)
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Mounting Snap-on mounting to compatible Eaton DIL contactors
Auxiliary Contacts 1 NO (95-96) + 1 NC (97-98) - Convertible
Reset Mode Manual reset (Automatic reset optional)