Technical Parameters
Parameter Specification
Product Series Eaton 5P
Product Type Line-Interactive UPS
Topology Line-Interactive
Nominal Output Power 1150 VA
Nominal Output Power in Watts 690 W (at a typical power factor of 0.6)
Input Voltage: 230 V AC (for specific regional variants)
Frequency: 50 Hz (for specific regional variants)
Connector: IEC 60320 C14
Output Voltage on Battery: Simulated Sine Wave
Output Connectors: IEC 60320 C13 outlets (typically 6-8)
Typical Runtime at Full Load A few minutes (e.g., 5-10 minutes, exact time depends on load)
Battery Type: Sealed, maintenance-free Lead-Acid battery
Replacement: User-replaceable
Automatic Voltage Regulation (AVR) Yes (Corrects brownouts and overvoltages without using the battery)
Communications USB port for connection to a computer for graceful shutdown
Display & Interface LED status indicators for power and battery status
Form Factor Compact Tower
Typical Applications Workstations, POS Systems, Network Devices (routers, switches), Home Office
Technical Parameters)
Parameter Specification
Product Series Eaton 5P
Product Type Line-Interactive UPS
Topology Line-Interactive
Nominal Output Power 850 VA
Nominal Output Power in Watts 510 W (at a typical power factor of 0.6)
Input Voltage: 230 V AC (for specific regional variants)
Frequency: 50 Hz (for specific regional variants)
Connector: IEC 60320 C14
Output Voltage on Battery: Simulated Sine Wave
Output Connectors: Multiple IEC 60320 C13 outlets (typically 6-8)
Typical Runtime at Full Load A few minutes (e.g., 5-10 minutes, exact time depends on load; longer at lower loads)
Battery Type: Sealed, maintenance-free Lead-Acid battery
Replacement: User-replaceable, hot-swappable cartridge
Automatic Voltage Regulation (AVR) Yes (Corrects brownouts and overvoltages without using the battery)
Communications USB port for connection to a computer for graceful shutdown
Display & Interface LED status indicators for power and battery status
Form Factor Compact Tower
Typical Applications Desktop Workstations, Entry-level Servers, POS Systems, Network Devices
Technical Parameters
Parameter Specification
Product Series Eaton 5P
Product Type Line-Interactive UPS
Topology Line-Interactive
Nominal Output Power 650 VA
Nominal Output Power in Watts 390 W (at a typical power factor of 0.6)
Input Voltage: 230 V AC (for specific regional variants)
Frequency: 50 Hz (for specific regional variants)
Connector: IEC 60320 C14
Output Voltage on Battery: Simulated Sine Wave
Output Connectors: IEC 60320 C13 outlets (typically 4-6)
Typical Runtime at Full Load A few minutes (e.g., 5-10 minutes, exact time depends on load)
Battery Type: Sealed, maintenance-free Lead-Acid battery
Replacement: User-replaceable
Automatic Voltage Regulation (AVR) Yes (Corrects brownouts and overvoltages without using the battery)
Communications USB port for connection to a computer for graceful shutdown
Display & Interface LED status indicators for power and battery status
Form Factor Compact Tower
Typical Applications Workstations, POS Systems, Network Devices (routers, switches), Home Office
Warranty Typically 2 years
Technical Parameters
Parameter Typical Specification (To be verified from datasheet)
Product Type Fixed, Polarized Electrolytic Capacitor
Capacitance 1000 µF (Microfarads)
Capacitance Tolerance Typically ±20% (e.g., M tolerance)
Rated Voltage (WV) e.g., 16V DC, 25V DC, 35V DC, 50V DC (This is a CRITICAL parameter to confirm)
Operating Temperature Range Typically -40°C to +85°C or +105°C
Leakage Current Specified by the manufacturer's formula (e.g., I ≤ 0.01CV or 3 µA, whichever is greater)
Dissipation Factor (tan δ) Specified at 120 Hz and 20°C (e.g., 0.12 max)
Lead Spacing e.g., 3.5 mm, 5 mm, 10 mm (Standard radial distances)
Polarization Polarized (Negative lead is typically marked by a stripe on the casing)
Lifetime Typically 1000 to 5000 hours at maximum rated temperature
Technical Parameters
Parameter Specification
Product Name Eaton Network-M3 Network Management Card
Product Type Internal UPS Communication Card
Compatibility Eaton 3S, 5P, 5S, 5SC, 9PX, 9SX, and other series UPS (Check compatibility list)
Network Interface 10/100 Mbps Ethernet (RJ-45 connector)
Management Protocols HTTP/HTTPS, SSH, SNMP v1/v3, Telnet, DHCP/BOOTP, DNS
Shutdown Support Supports graceful shutdown for Windows, Linux, VMware, Mac OS, and other major operating systems
Environmental Monitoring Yes (via RJ-11 port for optional EATON T/H probe)
Additional I/O One Dry Contact relay output (for external alarm)
Power Supply Powered directly by the host UPS
Configuration Via integrated web browser interface or Eaton software (e.g., Intelligent Power Manager)
Security Features User authentication (multiple user levels), SSL/SSH encryption, SNMP v3
Firmware Field-upgradable
Certifications CE, cULus, RoHS
Technical Parameters
Parameter Specification
Product Series Eaton 93E
Product Type Metered, Switched (by branch) PDU, Vertical (0U)
Nominal Input Power 40 kVA / 40 kW (Assume PF=1.0)
Input Type 3-Phase + Neutral + Ground
Input Voltage 200/208 V AC or 400/415 V AC (Specific voltage to be confirmed)
Input Current Typically 100 A or 60 A (depending on the specific voltage rating)
Frequency 50/60 Hz
Output Outlets Multiple outlet banks (Typically IEC C13/C19, NEMA, or a combination)
Branch Circuit Breakers Multiple branches (e.g., 1P or 3P breakers, 16A, 20A, or 32A)
Monitoring & Control Metering: Input current (per phase), voltage (L-N, L-L), power (kW), energy (kWh), power factor
Switching: Individual branch circuit control (ON/OFF/reboot)
Communication: Built-in Network Card (10/100/1000 Ethernet)
Protocols: Web, SSH, SNMP, Telnet
Display Local LCD for status and basic metrics
Form Factor Vertical (0U)
Mounting Zero U, vertical mounting in 19-inch rack
Management Features Power sequencing, alarm thresholds, event logging, user access control
Standards Compliance UL 60950-1, cULus, CE, RoHS
Technical Parameters
Parameter Specification
Product Series Eaton PW9100 iSeries
Product Type Intelligent, Switched PDU with Environmental Monitoring
Nominal Input Power 1000W (Total load capacity)
Input Connection Plug: IEC 60320 C14 or C20 (Region-specific cord attached)
Input Voltage 100-125 V AC / 200-240 V AC (Auto-sensing)
Input Current 12A @ 100V / 16A @ 125V / 10A @ 200-240V
Frequency 50/60 Hz
Output Outlets 10 x IEC C13 (Typical configuration, may vary)
Outlet Control Individual outlet switching (per outlet ON/OFF/reboot)
Monitoring & Control Metering: Aggregate current (A), voltage (V), power (kW), energy (kWh)
Switching: Individual outlet control
Environmental: Ports for external temperature & humidity sensors
Communication: Built-in 10/100 Mbps Network Card
Protocols: Web, SSH, SNMP, Telnet
Display Local backlit LCD for status and metrics
Form Factor Horizontal 2U Rackmount
Mounting 19-inch rack, 2 Rack Units (2U) high
Management Features Power sequencing, alarm thresholds, event logging, user access control
Standards Compliance UL 60950-1, cULus, CE, RoHS
Technical Parameters
Parameter Specification
Product Series Eaton 93PS
Product Type Metered, Switched (by branch) PDU, Vertical (0U)
Nominal Input Power 15 kVA / 15 kW
Input Connection Plug: NEMA L5-20P or L6-20P (20A, 120/208/240V) [Confirm exact type from datasheet]
Input Voltage 120/208/240 V AC (Auto-sensing)
Input Current 20 A
Frequency 50/60 Hz
Output Outlets 15 (Typically a mix of NEMA 5-15R and/or 5-20R, arranged in 15A branched groups)
Branch Circuit Breakers Multiple 15 A branch breakers
Monitoring & Control Metering: Input current, voltage, power (kW), energy (kWh)
Switching: Individual outlet/branch control
Communication: Built-in Network Card (10/100 Ethernet)
Protocols: Web, SSH, SNMP, Telnet
Display Local LCD for status and basic metrics
Form Factor Vertical (0U)
Mounting Zero U, vertical mounting in 19-inch rack
Management Features Power sequencing, alarm thresholds, event logging
Standards Compliance UL 60950-1, cULus, CE, RoHS
Technical Parameters
Parameter Specification
Product Series Eaton EATS
Product Type Automatic Transfer Switch (ATS)
Rated Power 30 kVA
Rated Operational Current (Ie) Typically 125 A (at 240V AC)
Poles 2 Poles
Rated Operational Voltage (Ue) 240 V AC (Single-Phase)
Withstand Current (Icm) Typically 10 kA (Please verify from datasheet)
Switching Mechanism Motor-Driven
Control Voltage Typically 24 V DC (sourced from the generator start circuit or external supply)
Time Delays Engine Start Delay: Adjustable
Transfer to Emergency Delay: Adjustable
Retransfer to Normal Delay: Adjustable
Engine Cool Down Delay: Adjustable
Standby Source Generator or other alternative AC source
Electrical Life Typically 10,000 operations (at rated current)
Mechanical Life Typically 50,000 operations
Mounting Suitable for panel or wall mounting
Standards Compliance UL 1008, CSA C22.2
Technical Parameters
Parameter Specification
Product Series Eaton 9PX Series
Product Type Double Conversion Online UPS (Rackmount)
Topology Online Double Conversion
Nominal Output Power 8 kVA / 7.2 kW (at 0.9 output power factor)
Input Voltage: 200/208/220/230/240 V AC (Auto-sensing)
Frequency: 50/60 Hz (Auto-sensing)
Connector: Typically hardwired for this power rating
Output Voltage: 200/208/220/230/240 V AC (User-selectable)
Frequency: 50/60 Hz ± 1 Hz (Synchronized to bypass)
Output Power Factor: 0.9
Typical Runtime Extended runtime at half load (3.6 kW) due to the "i" configuration. Exact minutes must be verified from the official datasheet.
Battery Type: Sealed, maintenance-free Lead-Acid batteries (internal)
Replacement: Hot-swappable, user-replaceable cartridge
Expansion: Supported via external battery packs (e.g., EBM series)
Efficiency >96% in online mode (at full load); >99% in Eaton GreenMode™
Communications Standard: USB, RS-232, Dry Contact
Optional: Slot for Network Management Card (e.g., IPM)
Display & Interface Color Graphical LCD
Form Factor 4U Rackmount (19-inch)
Typical Applications Data Centers, Server Rooms, Large Network Closets, Virtualization Hosts
Warranty Typically 3 years (including battery)