Parameter Specification
Product Series Eaton PLHTX (Accessory for PLH/PLHT MCB)
Model Number PLHTX-D100/4
Description Residual Current Release Module, for 4-Pole MCB, 100A
Compatible With Eaton PLH/PLHT series, 4-pole, 100A Miniature Circuit Breaker
Rated Current of Assembly 100 A
Number of Poles 4 Poles (3 Phase + Neutral)
Rated Residual Operating Current (IΔn) 30 mA
Residual Current Type Type A (for alternating and pulsating direct currents)
Rated Voltage 400V AC (3P+N)
Mounting Snaps onto the side of a compatible PLH/PLHT MCB on a DIN Rail.
Standards & Certifications IEC 61009-1, CE
Parameter Specification
Product Series Eaton PLD101X (Accessory for PL10 MCB)
Model Variants PLD101X-C10 (for 10A MCB), PLD101X-C40 (for 40A MCB)
Description Residual Current Release Module, for 1P+N MCB, C-Curve
Compatible With Eaton PL10 series, 2-pole (1P+N), C-Curve Miniature Circuit Breakers
Rated Current of Assembly 10 A (for C10) / 40 A (for C40)
Number of Poles 2 Poles (1 Phase + Neutral)
Rated Residual Operating Current (IΔn) Typically 30 mA
Residual Current Type Typically Type A
Rated Voltage 230V AC (1P+N)
Mounting Snaps onto the side of a compatible PL10 MCB on a DIN Rail.
Standards & Certifications IEC 61009-1, CE
Parameter Specification
Product Series Eaton PL9X (Accessory for PL9 MCB)
Model Number PL9X-C32
Description Residual Current Release Module, for 1P+N (2-Pole) MCB, 32A
Compatible With Eaton PL9 series, 2-pole (1P+N), 32A Miniature Circuit Breaker
Rated Current of Assembly 32 A
Number of Poles 2 Poles (1 Phase + Neutral)
Rated Residual Operating Current (IΔn) Typically 30 mA
Residual Current Type Typically Type A
Rated Voltage 230V AC (1P+N)
Mounting Snaps onto the side of a compatible PL9 MCB on a DIN Rail.
Standards & Certifications IEC 61009-1, CE
Parameter Specification
Product Series Eaton PL9X (Accessory for PL9 MCB)
Model Number PL9X-B40
Description Residual Current Release Module, for 3-Pole MCB, 40A
Compatible With Eaton PL9 series, 3-pole, 40A Miniature Circuit Breaker
Rated Current of Assembly 40 A
Number of Poles 3 Poles (3 Phase)
Rated Residual Operating Current (IΔn) Typically 30 mA
Residual Current Type Typically Type A
Rated Voltage 400V AC (3P)
Mounting Snaps onto the side of a compatible PL9 MCB on a DIN Rail.
Standards & Certifications IEC 61009-1, CE
Parameter Specification
Product Series Eaton PL9X
Model Number PL9X-C63
Description Residual Current Release Module, for 4-Pole MCB, 63A
Compatible With Eaton PL9 series, 4-pole, 63A Miniature Circuit Breaker
Rated Current of Assembly 63 A
Number of Poles 4 Poles (3 Phase + Neutral)
Rated Residual Operating Current (IΔn) Typically 30 mA
Residual Current Type Typically Type A
Rated Voltage 400V AC (3P+N)
Mounting Snaps onto the side of a compatible PL9 MCB on a DIN Rail.
Standards & Certifications IEC 61009-1, CE
Parameter Specification
Product Series Eaton PL10X
Model Number PL10X-C32
Description Residual Current Release Module, for 4-Pole MCB, 32A
Compatible With Eaton PL10 series, 4-pole, 32A Miniature Circuit Breaker
Rated Current of Assembly 32 A
Number of Poles 4 Poles (3 Phase + Neutral)
Rated Residual Operating Current (IΔn) Typically 30 mA
Residual Current Type Typically Type A
Rated Voltage 400V AC (3P+N)
Mounting Snaps onto the side of a compatible PL10 MCB on a DIN Rail.
Standards & Certifications IEC 61009-1, CE
Parameter Specification
Product Series Eaton PL10X (Accessory for PL10 MCB)
Model Number PL10X-D20
Description Residual Current Release Module, for 4-Pole MCB, 20A
Compatible With Eaton PL10 series, 4-pole, 20A Miniature Circuit Breaker
Rated Current of Assembly 20 A
Number of Poles 4 Poles
Rated Residual Operating Current (IΔn) Typically 30 mA
Residual Current Type Typically Type A
Rated Voltage 400V AC (3P+N)
Mounting Snaps onto the side of a compatible PL10 MCB on a DIN Rail.